ADTRAN 234 quick start Specifications, Features

Page 1

Quick Start Guide

For more detailed documentation, visit us online at www.adtran.com

TOTAL ACCESS 234 SHDSL NTU

P/N 1200708L1

 

 

￿￿￿ ￿￿￿

CONNECT THE CONSOLE INTERFACE

CONFIGURE GATEWAY IP ADDRESSES/SUBNET MASK

Before connecting to the Total Access 234 console interface, you will need the following items: VT100 terminal or PC (with VT100 terminal emulation software) and a straight through serial cable with a DB-9 (male) connector on one end and the appropriate interface for your terminal (or PC) on the other.

1.Connect the DB-9 (male) connector of your serial cable to the console port on the rear panel of the unit.

2.Connect the loose end of the serial cable to the VT100 terminal or PC (with terminal emulation software).

3.Open a VT100 terminal session to the Total Access 234 using the following settings: 9600 baud, 8 data bits, no parity bits, and 1 stop bit. Press <Enter> to activate the ADTRAN Command Line Interface (CLI).

SPECIFICATIONS

DC Input Power

12 VDC nominal (8.5 VDC min, 18 VDC max); ITU-T standards: G.991.2

Diagnostics & Test

Self-diagnosis; local loopback; remote loopback

EMC Emissions

EN55022:1998 Class B; FCC Part 15 Class B

EMC Immunity, Power

EN55024:1998; EN61000-3-2; EN61000-3-3; Telstra 1563; K.21 (2004)

Fault, and Lightning

Enhanced

Electrical Safety

EN60950; AS/NZS 60950; UL60950 3rd ed.;

 

CSA C22.2 No. 60950 3rd ed.; IEC 60950 CB Scheme

Telecom

S043.2; G.991.2

Environmental

Operating Temp: 0oC to 50oC; Storage Temp: -20oC to 70oC

*Note: No stacking should be done at 50oC. Up to three units can be stacked at room temperature.

 

Humidity: 95 percent noncondensing

Dimensions

9.3 inches W x 2.1 inches H x 6.1 inches D

Connectors

SHDSL Port: RJ-45; 135 ohms; TNV-3 rated

 

10/100BaseT Ethernet: RJ-45

 

Console Port: DB-9 female

 

Power Input: Kycon KPJ-3S snap & lock or equivalent

Configure the Gateway IP addresses and subnet mask by following these steps. If you are not sure what IP address to assign, please contact your network administrator.

1.Enter enable to activate the Enable command security mode.

2.When prompted, enter the enable password (if configured).

3.Enter config terminal to activate the Global configuration mode.

4.Enter bre lan-gw10.26.12.12wan-gw100.26.12.12 mask 255.255.255.0* to assign LAN and WAN Gateway IP addresses and subnet mask.

*Note: Underlined text represents example entries only. Modify them to match your configuration.

5.Enter exit to return to the Enable configuration mode.

6.Enter copy running-config startup-config to save the running configuration to the unit’s non-volatile memory (NVRAM).

FEATURES

One integrated EIA-232 configuration port (DCE)

One integrated 10/100BaseT Ethernet port

2-Wire/4-Wire SHDSL interface

WAN Protocol: ATM

Command Line Interface (CLI)

Management - EOC/CLI using Virtual Terminal

Front panel LEDs

Wall mounting available with additional parts

Table standoff cannot be used with this unit.

Quick Start Guide, 61200708L1-13B, January 2005

Technical Support 1-888-4ADTRAN or +1-256-963-8716

Copyright © 2005 ADTRAN, All Rights Reserved

Image 1
Contents Features SpecificationsColor Indication Total Access 234 Leds LED10/100BASET Ethernet Port Pinout Pin Name Description