8.Perform a circuit test to verify proper circuit operation.
9.Replace the cover assembly
10.Reattach the cover on the base.
3. REPLACEMENT PARTS
The environmental housing contains surge arrestors and an
Part number: 1150083L1 | 4 surge arrestors and the |
| insertion/extraction tool |
Part number: 3273.010 | O ring |
4. MAINTENANCE
The T400 Single Environmental Housing requires no routine maintenance to function properly.
Electrical shock can occur if surge arrestor replacement is attempted before removing the powering modules.
In cases where lightning is the suspected cause of circuit pack failure, ADTRAN recommends replacing all surge arrestors within the environmental housing. The surge arrestors are field replaceable as detailed in section 2.
The cover assembly
5. WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within ten years from the date of shipment, if the product does not meet its published specifications or if it fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Equipment Warranty and Return Policy and Procedure.
Return Material Authorization (RMA) is required prior to returning equipment to ADTRAN. ADTRAN does not recommend that repairs be performed in the field.
For service, RMA requests, or further information, contact one of the following numbers:
ADTRAN Customer Service: |
|
Applications Engineering | (800) |
| |
Technical Support | (800) |
Sales | (800) |
RMA (Repair Service) | (205) |
Repair and Return Address:
ADTRAN, Inc.
Customer Service Department
901 Explorer Boulevard
Huntsville, Alabama
4 |
| Section |