ADTRAN DE-4E specifications Control Port Operation, Abbreviation Definition

Page 7

5. CONTROL PORT OPERATION

The FT1 DP provides a faceplate-mounted DB-9 connector that supplies an RS-232 interface for connection to a controlling terminal. The pinout of the DB-9 is illustrated in Figure 5.

The terminal interface operates at data rates from

2.4 kbps to 19.2 kbps. The asynchronous data format

is fixed at 8 data bits, no parity, and 1 stop bit. The supported terminal type is VT-100 or compatible.

NOTE

If you are using a personal computer (PC) with terminal emulation capability, be sure to disable any power saving programs. Otherwise, communication between the PC and the HDSL unit may be disrupted, resulting

6

7

8

9

1

2 TXD (Transmit Data)

3 RXD (Receive Data)

4

5 SGN (Signal Ground)

in misplaced characters or screen timeouts.

Operation

Abbreviations used in the screen diagrams are detailed

in Table 5.

A terminal session is initiated by entering multiple

Figure 5. RS-232 (DB-9) Pin Assignments

Table 5. Definition of Screen Abbreviations

 

Abbreviation

Definition

 

 

 

 

 

 

 

ES

Errored seconds

 

 

DS1 (SF)

Second in which a BPV or frame bit error occurs

 

 

DS1 (ESF) ....

Second in which a BPV or CRC error occurs

 

 

DSL

Second in which a CRC error occurs

 

SES

Severely errored seconds

 

 

DS1 (SF)

Second in which 1554 BPVs or 8 frame bit errors occur

 

 

DS1 (ESF) ....

Second in which 1544 BPVs or 320 CRC errors occur

 

 

DSL

Second in which 165 CRC errors occur

 

UAS

Unavailable seconds

 

 

DS1

Second in which there is a loss of signal or sync

 

 

DSL

Second in which there is a loss of signal or sync

 

SF

Superframe format

 

ESF

Extended superframe format

 

B8ZS

Bipolar with 8-zero substitution

 

AMI

Alternate mark inversion

 

LBO

Line build-out

 

 

 

BPV

Bipolar violation

 

 

DS1

Second in which a bipolar violation occurs

 

NIU

T1 network interface unit

 

S/N

Serial number

 

 

 

15M

Fifteen-minute period

 

24H

Twenty-four-hour period

 

 

 

 

 

 

 

 

 

 

61245207L2-5C

Section 61245207L2-5, Issue 2

7

Image 7
Contents Description L2-5C Issue 3, July Clei Code # D4D31R8DGeneral Revision HistoryProtected Loopback InstallationProtected Loopback Mode Requirement Time Slot AllocationSW1 Option Settings Signaling Disabled Indicators Description Faceplate IndicatorsFT1 DP Option Selections FT1 DP Bantam Jacks DSL System TestingConnections Bantam Jack DescriptionOperation Control Port OperationAbbreviation Definition Introductory Menu Screen Current System Status Screen Performance History Screen Self-Test Options Screen Troubleshooting Screen Loop Insertion Loss Data DSL Deployment GuidelinesWarranty and Customer Service MaintenanceTroubleshooting Procedures Product SpecificationsFT1 DP Product Specifications L2-5, Issue 61245207L2-5C Appendix a FT1 Loopbacks Figure A-4. FT1 Repeater # 1 or 2 Network Loopback Loopback ACTIVATION/DEACTIVATION