ADC WBS-3190 manual System, Test Access, Alarms, Loopbacks, User Interface, Power, Environmental

Page 7

6 / 0 7 • 1 0 4 7 3 2 A E HiGain® Wideband 3190

HiGain® Wideband 3190

Integrated SONET/DS3 Multiplexer for HDSL/HDSL2/HDSL4

SYSTEM

 

Wander (looped):

0.3 UI max (1 UI = 648 ns)

Narrow Wideband Jitter:

0.3 UI max

Narrowband Jitter (looped):

0.1 UI max

TEST ACCESS

 

DSX-1:

 

“210” Bantam Jacks:

Bridging, splitting/line, splitting/drop; wire

 

wrapped posts on chassis backplane

Metallic:

Wire wrapped posts on chassis backplane

 

(HMS-358 only)

ALARMS

 

ACO and visual alarms:

major, critical, minor,

LOOPBACKS

Supports all standard in-band and out-of-band

 

loopback modes

USER INTERFACE

 

Craft Port:

RS-232 (DCE) at line unit and remote unit

OSS Interface:

RS-232 (DTE) at central office chassis X.25

Front Panel:

4-character display, status LED, system options

 

buttons at line unit, status LEDs

POWER

 

CO Supply:

-48 VDC (nom.) (-42.5 VDC to -56.5 VDC)

ENVIRONMENTAL

 

Each Span:

CSA design rules (e.g. 9 kft @ 26 AWG or 12

 

kft @ 24 AWG, no load coils, bridged taps per

 

CSA guidelines)

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1



Image 7
Contents Spec Sheet FeaturesWideband Management DS3 Multiplexer Standard FeaturesSTS-1 Multiplexer Standard Features HDSL/HDSL2/HDSL4 Industry-Leading BenefitsSpan Elements Outdoor Span Element HousingOutdoor Remote Element Housing Description Catalog Number CO ElementsHWM-02B Description Catalog Number Indoor Remote Element HousingIndoor Enclosure Accessories HWM-T01HDSL2 Transmission Hdsl TransmissionSystem Test AccessAlarms PowerSpec Sheet