ADC SignalOn Series manual Actives Forward Path Amplifier Actives Amplifier Modules

Page 11

5 / 0 8 • 1 0 2 7 2 1 A E SignalOn® Series

SignalOn® Series

Actives: Forward Path Amplifier

Actives: Amplifier Modules

 

 

 

Amplifier

 

 

 

(front view)

O r d e r i n g I n f o r m a t i o n

 

 

 

 

 

 

 

Description

 

 

 

Catalog Number

 

 

 

 

Forward Path Amplifier Modules

 

 

 

 

 

 

 

BNC connector

 

20 dB

 

N-MAB20FA

 

 

 

 

 

 

 

30 dB

 

N-MAB30FA

 

 

 

 

 

F connector

 

20 dB

 

N-MAF20FA

 

 

 

 

 

 

 

30 dB

 

N-MAF30FA

 

 

 

 

 

 

 

 

 

 

Performance Attribute

 

20 dB Forward Amplifier

30 dB Forward Amplifier

 

 

 

 

 

Bandwidth

 

50-1000 MHz

50-1000 MHz

 

 

 

 

 

Optimum RF input

 

+20 dBmV per channel

+10 dBmV per channel

 

 

 

 

 

Minimum full gain

 

20.0 dB

30.0 dB

 

 

 

 

 

Gain adjustment range

 

10 +/-1 dB in 0.5 dB steps

10 +/-1 dB in 0.5 dB steps

 

 

 

 

 

Tilt adjustment range

 

10 +/-1 dB @ 50 MHz in 0.5 dB steps

10 +/-1 dB @ 50 MHz in 0.5 dB steps

 

 

 

 

 

Gain flatness

 

+/- 0.4 dB from 50 to 870 MHz

+/- 0.45 dB from 50 to 870 MHz

 

+/- 0.5 dB from 870 to 1000 MHz

+/- 0.65 dB from 870 to 1000 MHz

 

 

 

 

 

 

 

Return loss,

 

-19.0 dB from 50 to 870 MHz

-18.0 dB from 50 to 870 MHz

input and output ports

 

-16.5 dB from 870 to 1000 MHz

-15.0 dB from 870 to 1000 MHz

 

 

 

 

 

Noise figure

 

7.3 dB from 50 to 870 MHz

5.7 dB from 50 to 870 MHz

 

7.6 dB from 870 to 1000 MHz

6.2 dB from 870 to 1000 MHz

 

 

 

 

 

 

 

CTB1

 

-73.1 dB

-78.9 dB

 

 

 

 

 

CSO1

 

-81.7 dB

-84.5 dB

 

 

 

 

 

IMD1

 

-78.2 dB

-83.7 dB

 

 

 

 

 

Monitor ports

 

-20 dB test point for both RF input and RF output

 

 

 

 

Power dissipation

 

17W max

 

 

 

 

Operating temperature

 

0 - 50 degrees C

 

 

 

 

Dimensions

 

8.55"H x 1.67"W x 7.81"D

 

 

 

 

Power connector

 

gold-on-gold, slide-on contacts

 

 

 

 

Thermal shock

 

Meets MIL-STD-202 Method 107

 

 

 

 

Office vibration

 

Meets GR-63-Core Section 5.4.2

 

 

 

 

Mechanical shock

 

Meets MIL-STD-202 Method 213

 

 

 

 

Accelerated aging

 

Meets MIL-STD-202 Method 108

 

 

 

 

NEBS

 

Meets NEBS Level 3

 

 

 

 

 

Note: Measured with 110 channel loading and optimum RF input level at full gain and no tilt. Specifications are typical worst-case numbers across the given frequency range, unless otherwise noted, and are subject to change without notice.

w w w . a d c . c o m

+ 1 - 9 5 2 - 9 3 8 - 8 0 8 0

1 - 8 0 0 - 3 6 6 - 3 8 9 1

11

Image 11
Contents Spec Sheet RF Signal Management8 1 0 2 7 2 1 a E SeriesDescription Catalog Number Passive Chassis RF Signal Management ChassisPower Kit Position, 1 RU ChassisPassives RF Splitter/Combiner Modules 5 MHz to 1 GHz RF Signal Management Passives Introduction1 a E SignalOn Description Plain Splitter/Combiner Modules Catalog Number 8 1 0 2 7 2 1 a E SignalOn SeriesMCF12M0 DC Value 8 1 0 2 7 2 1 a E SignalOnCircuit Quantity Application TypeDescription Catalog Number Conditioning and monitor module schematicNebs Level 3 compliant Way Splitter Catalog Number Connector TypeBand Satellite Splitter Description Catalog Number Band Satellite Splitter ModulesAmplifier RF Signal Management Actives IntroductionPosition, 5 RU Powered Chassis Position, 2 RU Powered ChassisActives Forward Path Amplifier Actives Amplifier Modules Specifications RF Signal Management Actives Power Supply ModulesDescription Catalog Number Redundant RF Switch Modules RF Signal Management Actives RF Switch Modules2 7 2 1 a E SignalOn Dual RF Switch ModuleDB Fixed Gain RF Signal Management Actives Reverse Path Amplifier ModulesTerminating Plugs RF Signal Management AccessoriesChassis Extender Brackets for Insertion/Withdrawal ToolsDescription Catalog Number Equalizer Pads DC Power Upgrade Kits forPower Supply Accessories Module Conversion Kits to install