INSTALLATION

Proper installation of the unit is essential for years of safe, reliable operation. Please read all instruction before installing the unit. Failure to follow these instructions can cause serious damage to the unit or vehicle and may void warranties.

SAFETY PRECAUTIONS

For the safety of the installer, vehicle operator, passengers and the community please observe the following safety precautions. Failure to follow all safety precautions and instructions may result in property damage, injury or death.

Qualifications - The installer must have a firm knowledge of basic electricity, vehicle electrical systems and emergency equipment.

Sound Hazard - Sound level from siren speaker (>120dBA @ 10 feet) may cause hearing damage. Do not operate siren without adequate hearing protection for you and anyone in immediate vicinity. (Ref. OSHA 1910.95 for occupational noise exposure guidelines)

Mounting - Mount the unit for easy access by the vehicle operator. DO NOT mount in air bag deployment area. Assure clearances before drilling in vehicle. To prevent internal damage mounting bolts must not enter case more than 1/4".

Wiring - Use wiring capable of handling the current required. Make sure all connections are tight. Route wiring to prevent wear, overheating and interference with air bag deployment. Install and check all wiring before connection to vehicle battery.

Testing - Test all siren functions after installation to assure proper operation. Test vehicle operation to assure no damage to vehicle.

Keep These Instructions - Keep these instructions in the vehicle or other safe place for future reference. Advise the vehicle operator of the location.

MOUNTING

The mounting bracket supplied can be installed above or below the unit. Choose a mounting location convenient to the operator and away from any air bag deployment areas. Inspect behind mounting area for clearance. Assure adequate ventilation to prevent overheating. Consider wire routing and access to connections, as well as microphone bracket placement. Install mounting bracket to vehicle using 1/4" hardware (not supplied).

If mounting in a rack or console, make sure that mounting bolts do not enter case more than 1/4".

May need to set RADIO VOLUME ADJUST inside the unit before final mounting and installation

A microphone clip along with mounting screws (CP3633) holds the microphone in place.

CP3571 Mounting Bracket

1/4-20 Bolt (CP3966)

Bolt must not pass through cover more than 1/4”

TB0321B

Page 3 of 8

10/18/03

Image 3
Contents Technical Bulletin Audio Mode Output Power SA-400-63 SpecificationsInput Power Siren Mode Output PowerInstallation Safety PrecautionsMounting Electrical Connections Wiring Harness ConnectionsOperation Power Output Adjust Radio Volume AdjustReturn ServiceProblems Symptom Possible Cause CheckDescription Parts

SA-400-63 14V, SA-400-63 28V, SA-400-63 PG specifications

The Carson SA-400-63 series represents a line of highly specialized power supplies designed for a multitude of applications in electrical engineering and technology sectors. The models within this series, specifically the SA-400-63 PG, SA-400-63 28V, and SA-400-63 14V, showcase Carson’s commitment to quality, durability, and efficiency in power supply technology.

One of the standout features of the SA-400-63 series is its versatility. The differing voltage outputs—28V and 14V—cater to specific applications, providing users with options that best suit their power requirements. This adaptability makes these power supplies ideal for powering various electronic devices, from industrial equipment to consumer electronics, ensuring reliable operation across a broad spectrum of environments.

Technologically, the SA-400-63 series incorporates advanced voltage regulation techniques. This ensures that users receive a steady and reliable power output, crucial for sensitive electronic systems that require stable voltage levels for optimal performance. Additionally, the series features built-in protection mechanisms such as overvoltage, overcurrent, and short-circuit protection. These safety features enhance the reliability of the units and safeguard connected devices from unexpected electrical conditions.

The thermal management design of the SA-400-63 models is another noteworthy characteristic. With efficient heat dissipation features, these power supplies maintain optimal operating temperatures, even under high loads. This not only extends the lifespan of the units but also ensures consistent performance over time, which is particularly advantageous for long-term applications.

Moreover, the SA-400-63 series is engineered with a compact form factor, allowing for easy integration into existing systems without requiring excessive space. This characteristic makes them particularly suitable for both portable and stationary applications, enhancing their versatility even further.

In terms of construction, the Carson SA-400-63 series is built to endure rugged conditions. With durable materials and a robust design, these power supplies are capable of withstanding the rigors of industrial use, making them a reliable choice for professionals operating under demanding circumstances.

In summary, the Carson SA-400-63 PG, SA-400-63 28V, and SA-400-63 14V represent the cutting edge of power supply technology. With their reliable voltage regulation, built-in safety features, efficient thermal management, and rugged construction, they meet the diverse needs of modern electronic applications, providing users with the assurance of consistent and dependable performance.