Carson SA-400-17 manual Mounting, Electrical Connections

Page 6

Page 6 of 12 SA-400-17 Installation and Operating Instructions

MOUNTING

The mounting bracket supplied can be installed above or below the unit. Choose a mounting location convenient to the operator and away from any air bag deployment areas. Inspect behind mounting area for clearance. Assure adequate ventilation to prevent overheating. Consider wire routing and access to connections, as well as microphone bracket placement. Install mounting bracket to vehicle using 1/4" hardware (not supplied).

If mounting in a rack or console, make sure that mounting bolts do not enter case more than 1/4".

ELECTRICAL CONNECTIONS

Electrical connections to the unit are made using the wiring harness supplied. If the unit needs service the connector can be easily removed without unwiring the harness.

The power supply for the unit must be capable of delivering peak currents up to 50 amps for adequate short circuit protection and reliable operation. The preferred source is directly at the vehicle battery. A fuse on the rear of the unit protects from overload.

Disconnect vehicle battery before making any electrical connections. Extend leads using adequately sized wiring and terminals or splices.

Wire Size and Termination - The diagram shows the minimum wire size used for each connec- tion, along with recommended lead color. If the wire is longer than 10 ft. use the next larger wire size. Use only high quality crimp connectors for installation on the vehicle.

Radio Input Connection (Optional) - Connect 1 lead to each terminal of the radio speaker or output connector. The input is isolated and polarity is not important. May need to set RADIO VOLUME ADJUST on side of unit.

Auxiliary Input Connection (Optional) - Used for Siren Control. Performs the same function as Siren push-button. Typically connected to the horn ring circuit of the vehicle or other momentary switch. See below for further details on activation polarity.

NOTE: Permanent disconnection of the vehicle horn is NOT recommended.

Traditional Auxiliary Input Activation - On earlier models of the SA-400, the auxiliary input is activated with positive (+VDC) AND negative (-VDC). A normally open horn ring circuit or switch is required for proper operation.

Possibly use this setting if the auxiliary input is wired for an earlier SA-400. See OPTION SWITCHES section for further details.

Polarity Selectable Auxiliary Input Activation - The auxiliary input may be activated with positive (+VDC) OR negative (-VDC).

See OPTION SWITCHES section for further details.

08/06/08

CP5012A

Image 6
Contents Siren Amplifier With Mechanical Tone Phone 888 577-6877 Fax 317Table of Contents Specifications General DescriptionUnpacking InstallationSafety Precautions QtySW-5 Not Used… Leave Off Option SwitchesAccessing Option Switches The cover is SW-6 SW-7 SW-8 Auxiliary Input Activation PolarityMounting Electrical ConnectionsBAT General Selector SwitchOperation PA VOLRadio Adjust Siren SwitchRadio Volume DIPService ProblemsParts and Accessories Part DescriptionLimited Warranty Return

SA-400-17 specifications

The Carson SA-400-17 is a versatile and powerful digital microscope that has gained significant recognition in the realms of education, research, and industry. This advanced microscope is designed for a wide range of applications, providing high-resolution imaging and ease of use.

One of the main features of the Carson SA-400-17 is its impressive magnification capabilities. It offers a magnification range from 40x to 400x, allowing users to observe intricate details of specimens with clarity. This level of magnification is particularly useful in fields such as biology, material science, and electronics, where understanding fine structures is essential.

The microscope is equipped with a high-resolution camera that captures images and videos in real-time. This feature is invaluable for documentation and analysis, enabling users to record their observations for future reference or presentations. The camera is supported by advanced imaging software, which allows for image enhancement, measurement, and annotation, further enriching the user experience.

Another notable technology integrated into the Carson SA-400-17 is its LED illumination system. This system provides bright and even lighting for the specimens, ensuring that details are not lost in shadows. The adjustable brightness feature allows users to tailor the lighting to their specific needs, making it suitable for various sample types.

The SA-400-17 is designed with user-friendliness in mind. Its ergonomic design and intuitive controls make it accessible for users of all skill levels. The device also features a sturdy base that ensures stability during use, which is crucial for achieving clear and focused images.

In terms of connectivity, the Carson SA-400-17 supports USB connectivity, enabling easy connection to computers for data transfer and analysis. This seamless integration with PCs enhances the capabilities of the microscope, allowing users to leverage advanced software tools for research and education.

Overall, the Carson SA-400-17 stands out due to its combination of practicality and advanced technology. With its high magnification, real-time imaging capabilities, and user-friendly design, it serves as an indispensable tool for educators, researchers, and professionals alike. Its adaptability to various fields ensures that it meets the diverse needs of its users while fostering a deeper understanding of the microscopic world.