VTX212
The Bottom Panel:
CAUTION |
RISK OF ELECTRIC SHOCK |
DO NOT OPEN |
AVIS: RISQUE DE CHOC ELECTRIQUE. |
NE PAS OUVRIR. |
WARNING: TO REDUCE THE RISK OF FIRE |
OR ELECTRIC SHOCK, DO NOT EXPOSE THIS |
EQUIPMENT TO RAIN OR MOISTURE. |
FUSE
100VAC: T2.5A | 250V | |
120VAC: T3A | 250V |
|
230V/240VAC: T1.6A | 250V |
MADE IN CHINA
FOR SLM ELECTRONICS
1400 FERGUSON AVE. ST. LOUIS, MO 63133 PATENT #5,032,796
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
EXTENSION |
| FOOTSWITCH |
|
| ||
|
| |||||
SPEAKER | DSP | CHANNEL | ||||
|
| BANK A | CLEAN | |||
|
| BANK B | SOLO/RHYTHM | |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
#3031613
INSERT
27 | 28 | 29 | 30 | 31 |
27:FUSE: The fuse protects the amplifier from damages caused by a faulty AC power source and/or other prob- lems. If the fuse opens, replace it ONLY with the same size and type. If fuses continue to fail, check the AC source
– if the source is okay, contact your Crate dealer for service information.
28:EXTENSION SPEAKER: Use this jack to connect the amplifier to an external speaker cabinet. This jack is wired in series with the internal speaker(s) which remain active when an extension speaker is connected.
29:DSP A/B FOOTSWITCH: Use this jack to connect one of the footswitch cables to the
30:CLEAN/SOLO/RHYTHM FOOTSWITCH: Use this jack to connect one of the footswitch cables to the three- button footswitch (supplied). This allows you to remotely switch between the Clean and Distortion channels and between the Solo and Rhythm channels. (See page 9.)
31:INSERT: Use this jack to connect an external signal processor to the amplifier. Use Crate’s STP201, STP202, or STP203
32:AC LINE CORD (not shown): This grounded power cord is to be plugged into a grounded power outlet, wired to current electrical codes and compatible with the voltage, power, and frequency requirements stated on the bot- tom panel. Do not attempt to defeat the safety ground connection.
Y-adapter and 2 cables:
| to Insert | TIP | RETURN | TIP | to Insert |
| jack | RING | SEND | RING | jack |
|
| SLEEVE | GROUND | SLEEVE |
|
| (STP201, 3' |
|
| (YPP117) |
|
| STP202, 6' |
|
|
| |
| STP203, 9') |
|
|
|
|
|
|
|
| TIP | RING |
| TIP |
| RING |
|
|
|
|
|
| ||
|
|
|
| MONO SHIELDED | |
|
|
|
| CABLES) | |
| to | to |
| to | to |
| effect | effect |
| effect | effect |
| "OUT" | "IN" |
| "OUT" | "IN" |
| jack | jack |
| jack | jack |
6 | External Effect |
| External Effect |