Agilent Technologies 89600 manual Anti-alias filters and alias exposure-free mode, Digitizer model

Page 7

3.2 Anti-alias filters and alias exposure-free mode

The broadband VSA can be configured to be essentially alias-free by using the full rate sampling mode and installing an external lowpass filter on the digitizer input. Use BNC-f to SMA-m and SMA-f to BNC-m adapters to connect the filter’s SMA connectors to the digitizer in case the digitizer has BNC connectors.

Table 3. External lowpass filters

Digitizer model

Cutoff frequency

Filter part number

U1066A-002 (DC438)

90 MHz

Mini-circuits BLP/SLP-90

U1066A-001 (DC440)

100 MHz2

Mini-circuits1

BLP/SLP-100

U1065A (DC252 (2 ch),

1650 MHz

Mini-circuits1

SLP-1650

DC282 (2 ch))

 

 

 

U1065A (DC222, DC252

2000 MHz

Mini-circuits1

SLP-2000

(1 ch), DC282 (1ch))

 

 

 

1.Mini-Circuits, Inc., 1-800-854-7949, www.minicircuits.com.

2.For the HF input a 300 MHz lowpass filter will avoid aliasing from signals above 300 MHz, but in-band and out-of-band aliasing is still possible since full rate mode is not supported with the HF input.

7

Image 7
Contents Application Note Table of Contents Range OverviewModel FrequencyRequired software revisions 89600 VSA softwareInstallation for standard operation Install 89600 VSA SoftwareInstallation for embedded operation I/O between computer and digitizer Hardware ConfigurationDigitizer model Anti-alias filters and alias exposure-free modeFilter part number Basic operation OperationSampling modes full rate and user rate User rate mode Full rate Differences from 89600 VSA operationUser rate Relationship of main time length, span, and sample rate Time Frequency Span Operating RegionOperating region curves for Agilent Acqiris digitizers Page Operating region span constraints Operating region with span and memory constraints Model No. Max span Recording limits for Acqiris digitizersChs Using the Alias Exposure Zone Checker Setting up the Alias Exposure Zone CheckerTrace C Trace a Page RF range Mixer If amp Remarks Appendix aPC Requirements to Run 89600 Software Characteristic Microsoft Windows XP ProfessionalAppendix B Appendix CMemory 4 Mpts Related literature list For More InformationRemove all doubt

89600 specifications

Agilent Technologies, a leading player in the test and measurement sector, has developed the 89600 VSA (Vector Signal Analysis) software, a powerful tool designed for a wide variety of signal analysis applications. This software is crucial for engineers and researchers developing and testing wireless communication systems, radar technologies, and other complex signal environments.

One of the main features of the Agilent 89600 is its capability to analyze both analog and digital signals with high precision and flexibility. It supports a broad range of modulation formats used in modern communication systems, including LTE, Wi-Fi, GSM, and many others. This extensive modulation support enables users to test their designs against industry standards and protocols, ensuring compliance and operational integrity.

The 89600 VSA software excels in its real-time analysis capabilities, which is critical for evaluating transient signal behavior and understanding time-varying signals. With its advanced algorithms and fast processing capabilities, users can perform real-time demodulation of complex signals, which is vital for debugging and optimizing communication systems. The software also supports offline analysis, allowing engineers to capture and analyze signals at their convenience.

Another standout characteristic of the 89600 software is its intuitive user interface, which streamlines the setup process and enhances user experience. The drag-and-drop functionality allows for easy configuration of measurement setups, while comprehensive visualization tools provide deep insights into the signal characteristics. Users can visualize modulation quality, spectral components, and error vectors through various graphical representations.

The software integrates seamlessly with Agilent's hardware spectrum analyzers and signal generators, offering a holistic solution for signal generation and analysis. It also supports a wide range of signal inputs, from hardware-based vector signal generators to recorded data files.

Moreover, the flexibility of the Agilent 89600 is enhanced through its modular architecture, which allows users to easily add new measurement capabilities via optional software packages. This adaptability ensures that the tool stays relevant as communication technologies evolve.

In summary, Agilent Technologies' 89600 VSA software combines advanced signal analysis capabilities with user-friendly features to provide a comprehensive solution for communication engineers. Its ability to handle multiple modulation formats, real-time analysis, and robust visualization tools makes it an essential resource for anyone involved in the development and testing of signal-based technologies.