SHM-B ASYNC

computing equipment for consistency.

3.Wire the SHM-B units back-to-back, eliminating the twisted-pair; see if you still have errors.

If you do have errors, then test each SHM individually in the following way: loopback one SHM’s Transmit-to-Receive by using two short pieces of wire. Connect that SHM to a dumb terminal and key in characters; look for a good loopback. A good loopback verifies a SHM-B in proper working condition.

If you don’t have errors, you have verified a problem with the twisted-pair cable.

SYMPTOM: Occasional data errors.

1.The transmission distance/bps data rate capability rate may have been exceeded. Refer to Chapter 1 for information about valid data transmission distances and bps rates.

2.There is a poor quality loop (four-wire circuit). Try using a different four-wire circuit, or rewire the existing circuit.

23

Image 24
Contents Short-Haul Modem B SHM-B Async SHM-B Async SHM-B Async SHM-B Async Trademarks Used in this Manual Specifications Distance miles/kmOperating Temperature 32 to 112F 0 to 50C SHM-B Async Introduction Installation Four-Wire ConnectionsSHM-B board 5-screw terminal block Wiring diagram for two SHM-B units EIA-232 ConnectionSwitch Settings EIA-232 Pin Connections on SHM-BPinning with DTE/DCE switch in the DCE position Flow Control ON/X-OFF Mode Activating the Loopback switch OperationSHM-B Async Rackmount Installation SHM-B Async Troubleshooting Guide SHM-B Async SHM-B Async SHM-B Async SHM-B Async SHM-B Async Copyright 2000. Black Box Corporation. All rights reserved