Black Box EncrypTight Enforcement Point (ETEP) Installation Guide manual Setting the Date and Time

Page 50

 

 

 

Setting the Date and Time

 

 

 

 

 

 

Table 19

Management port autoneg command description

 

 

 

 

 

Attribute

 

Description

 

 

enable

 

Enables auto-negotiation on the management port. This is the default

 

 

 

 

setting.

 

 

disable

 

Disables auto-negotiation on the management port. Use this setting to

 

 

 

 

manually configure link speed and flow control.

 

 

speed

 

[100m-full 10m-full 100m-half 10m-half]

 

 

 

 

When auto-negotiation is disabled, the speed attribute specifies the link

 

 

 

 

speed and duplex setting. The speed defaults to 100m-full.

 

 

flow control

 

[on off]

 

 

 

 

When auto-negotiation is disabled, this attribute configures the flow control

 

 

 

 

setting to be on or off. The flow control setting defaults to on.

 

 

 

 

 

 

Example

The following example sets the management port IPv4 address, subnet mask, and gateway for the ETEP as shown in Figure 34. Auto-negotiation is left at its default setting of enabled.

admin> configure

config> management-interface

man-if>ip 192.168.10.10 255.255.255.0 192.168.10.1 man-if>exit

The next example sets the management IPv4 address and subnet mask, and omits the default gateway. The default gateway can be omitted when the management station and the ETEP management port and are wired directly to each other on the same subnet. Auto-negotiation is disabled. The link speed is set to 100 Mbps full-duplex and flow control is turned on.

admin> configure

config> management-interface

man-if>ip 192.168.10.10 255.255.255.255 man-if>autoneg disable 100m-full on man-if>exit

The following example sets an IPv6 address, prefix length, and default gateway on the management port.

admin> configure

config> management-interface

man-if>ip6 2001:DB8::211:11FF:FE58:743/64 2001:DB8::20F:F7FF:FE84:BFC2 man-if>exit

config>

Setting the Date and Time

Setting the date and time on the ETEP helps ensure that the appliance’s time can be synchronized properly with other ETEPs or components in the EncrypTight system.

The time zone on the ETEP is set to UTC 0 (Coordinated Universal Time), and is not user configurable. Enter the date and time relative to UTC 0, also referred to as Greenwich Mean Time (GMT). To calculate

ETEP Installation Guide

51

Image 50
Contents EncrypTight Enforcement Point Etep Installation Guide Table of Contents Initial Setup Index Table of Contents Etep Installation Guide About This Document Contacting Black Box Technical SupportAbout This Document Etep Installation Guide Product Overview Etep IntroductionMultipoint Ethernet Encryption using EncrypTight Front Panel Connectors ET0010A Physical DescriptionStatus Indicators Indicator Light State IndicationET0100A Physical Description Rear PanelLED Indicators ET0100A Front Panel ConnectorsET0100A Front Panel LED Indicators ET0100A Rear PanelET1000A Front Panel Connectors ET1000A Physical DescriptionET1000A LED Indicators ET1000A Front Panel LED IndicatorsPower Supply # ET1000A Rear PanelCategory Feature FeaturesEtep Feature Summary Etep Hardware ComparisonSpecification SpecificationsET0010A Mechanical and Environmental Specifications CategoryET0100A Mechanical and Environmental Specifications Category SpecificationET1000A Mechanical and Environmental Specifications Before You Start InstallationSafety Guidelines Software How it’s used Vendor Software RequirementsThird party management station software Ambient temperature Etep Site PreparationFirewall ports Installing the ET0010AFirewall Ports Standalone Cipher Protocol Port Description ETEPs EngineUnpacking the Shipping Carton ET0010A Installation StepsCabling Requirements ET0010A ET0010A Standard CablesInstallation Instructions ET0010A Accessory screws and feetTo install the Etep in a rack Bottom rear view of the ET0010A, with rack mount bracketsInstallation Front view of ET0010A mounting brackets and power supply To install the Etep on a solid surfaceScrew holes for rubber feet installation on bottom of unit Connecting the Cables ET0010A To cable the ET0010APowering On the ET0010A ET0010A CablingET0100A Installation Steps Installing the ET0100ATo power on the Etep Cabling Requirements ET0100AET0100A Standard Cables Rack-Mount Installation ET0100AUnpacking the Shipping Carton ET0100A ET0100A Port Cabling Supplied byConnecting the Cables ET0100A To cable the ET0100APowering on the ET0100A To power on the ET0100AInstalling the ET1000A Improperly seated ET0100A power cableET1000A Standard Cables ET1000A Installation StepsCabling Requirements ET1000A ET1000A Port Cabling Supplied byRack Mount Installation ET1000A Unpacking the Shipping Carton ET1000AConnecting the Cables ET1000A To install the ET1000A in a rackPowering on the ET1000A To cable the ET1000ADual power supplies on the ET1000A rear panel To power on the ET1000AAppliance model Operational code Shutting Down the EtepShutdown operational codes To shut down the Etep from the CLI Related topicLogging In Through a Serial Link Initial SetupOverview About the management port IP address, mask and gateway Configuring the Management PortTo log in to the CLI via a serial link Management Port Default Gateway About auto-negotiation Link speeds on the management portTo configure the management port Link speeds on the management portAttribute Description Setting the Date and TimeManagement port autoneg command description Etep Throughput Speeds Entering a Throughput LicenseTo set the date and time Model Available ThroughputManaging the Etep Configuration ExampleTo add a license from the command line To view the Etep throughput speedEtep CLI User Guide EncrypTight User Guide Maintenance Preventative MaintenanceTo replace a power supply in the ET1000A Obtaining a License for Replacement UnitsReplacing the ET1000A Power Supply What To Do If an Appliance FailsPower cord is removed from power supply # Tamper Switch and Zeroization EtemsRS-232 Serial Cable ET0010A To recover the Etep following zeroizationCable Pinouts RJ-45 Pin DB-9 PinRS-232 Serial Cable ET0100A/ET1000A PinLED Indicators TroubleshootingSymptoms and Solutions Symptom Explanation and Possible SolutionSymptom Explanation and Possible Solutions Error StateError State Symptoms and Solutions ET0010A Self-Tests Diagnostic Code DisplayStatus Codes ET0010A ET0010A Operational CodesET0100A/ET1000A Operational Codes Diagnostic Codes ET0100A and ET1000AET0100A/ET1000A Self-Tests RoHS Directive Appendix a Environmental and Regulatory InformationWeee Directive Regulatory Information ET0010A Regulatory InformationET0100A Regulatory Information European NoticeET1000A Regulatory Information ET0100A CablingNormas Oficiales Mexicanas NOM Electrical Safety Statement Instrucciones DE SeguridadEnvironmental and Regulatory Information Index Index See also license entering Index Etep Installation Guide Black Box Tech Support FREE! Live /7

EncrypTight Enforcement Point (ETEP) Installation Guide specifications

The Black Box EncrypTight Enforcement Point (ETEP) is a robust solution designed to enhance data security by ensuring that sensitive information is securely transmitted and stored. This article provides a comprehensive installation guide that highlights the main features, technologies, and characteristics of ETEP.

The EncrypTight ETEP operates by providing a secure gateway between different networks. It employs advanced encryption algorithms to safeguard data from potential threats, ensuring that unauthorized access is thwarted. A core feature of the ETEP is its ability to support a range of encryption standards, including AES, RSA, and ECC, thus allowing organizations to choose the most suitable protocols for their specific needs.

One of the standout technologies integrated within the ETEP is its end-to-end encryption capability. This ensures that data remains encrypted during transmission from the sender to the receiver, making it virtually impossible for any third-party entities to decipher the information even if they manage to intercept it.

The ETEP also boasts a user-friendly interface that simplifies installation and configuration processes. Administrators can easily set up the system without requiring extensive technical knowledge. Furthermore, the system is designed to integrate seamlessly with existing IT infrastructure, ensuring minimal disruption during deployment.

Another critical characteristic of the ETEP is its scalability. As businesses grow and evolve, the ETEP can be easily adjusted to accommodate increased data traffic and changing security requirements. This flexibility makes it an ideal solution for organizations of all sizes, from small businesses to large enterprises.

Moreover, the ETEP employs state-of-the-art threat detection and response mechanisms. It continuously monitors network activity, identifying anomalies that may indicate potential security breaches. This proactive approach ensures that organizations can respond swiftly to threats, thereby minimizing potential damage.

The installation of the Black Box EncrypTight ETEP typically involves the following steps: first, assess the current network architecture; second, select the appropriate hardware and software components; third, configure encryption settings; and finally, conduct thorough testing to ensure the system is functioning as expected.

In conclusion, the Black Box EncrypTight Enforcement Point installation is a crucial step in bolstering an organization’s data security framework. With its advanced features, reliable technologies, and user-centric design, the ETEP stands out as an essential tool for businesses looking to safeguard their sensitive information against ever-evolving cybersecurity threats.