Connecting Cisco ISDN PRI Network Modules to the Network

Channelized T1/ISDN PRI Network Modules

Figure 4

Connecting a Channelized T1/E1 PRI Network Module with G.703 to a Networking

 

Device

NM-1CE1T1-PRI

RX

TX

 

CD

LP

MON

MON

RA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T1

E1-BAL

AIM

C0

LA

CTLR 0

E1-UNBALEN

88639

Channelized T1/ISDN PRI Network Modules

This section provides information about the following network modules for Cisco modular routers:

1-port channelized T1/ISDN PRI network module (NM-1CT1 or CPANM-1CT1) (see Figure 5). This module is also referred to as the 1-port CT1/PRI network module.

2-port channelized T1/ISDN PRI network module (NM-2CT1 or CPANM-2CT1) (see Figure 6). This module is also referred to as the 2-port CT1/PRI network module.

Figure 5

 

1-Port Channelized T1/ISDN PRI Network Module

cT1

 

 

 

PRI

 

 

 

REMOTE ALARM LOCAL ALARM

LOOPBACK

CARRIER DETECT

EN

 

 

 

CTRLR 0

H7460

CT1/PRI-U port (DB-15)

Figure 6

 

 

 

2-Port Channelized T1/ISDN PRI Network Module

cT1

REMOTE ALARM LOCAL ALARM

LOOPBACK

CARRIER DETECT

EN

PRI

 

 

 

 

 

 

 

 

CTRLR 1

 

REMOTE ALARM LOCAL ALARM

LOOPBACK

CARRIER DETECT

EN

CTRLR 0

CT1/PRI-U ports (DB-15)

H7461

Connecting CT1/PRI Modules to the Network

To connect a CT1/PRI module to the network, use a DB-15-to-DB-15 T1 serial cable to connect the CT1/PRI port to a T1 channel service unit (CSU). (See Figure 7.) These ports are color-coded tan.

Connecting Cisco ISDN PRI Network Modules to the Network

5

Image 5
Contents Connecting Cisco Isdn PRI Network Modules to the Network Channelized T1/E1 PRI Network Modules with G.703 Modular Access RouterCisco Yes Cisco 37 703 Channelized T1/ISDN PRI Network Modules Connecting CT1/PRI Modules to the NetworkChannelized T1/ISDN PRI with CSU Network Modules Connecting a CT1/PRI Module to a T1 CSUChannelized E1/ISDN PRI Balanced 120-Ohm Network Modules Connecting CT1/PRI CSU Modules to the NetworkFunction CE1/PRI Module Jumper SettingsConnecting CE1/PRI-B Modules to the Network E1 CSU Port Channelized E1/ISDN PRI Network Module Unbalanced Channelized E1/ISDN PRI Unbalanced 75-Ohm Network ModulesPRI Module LEDs Connecting CE1/PRI-U Modules to the NetworkChannelized T1/E1 PRI Network Module with G.703 LEDs MeaningColor Meaning CT1/PRI Network Module LEDsPort CT1/PRI Network Module LEDs CT1/PRI CSU Network Module LEDsPort CE1/PRI Network Module LEDs CE1/PRI Network Module LEDsRelated Topic Document Title Upgrading Isdn PRI Network ModulesRelated Documents Connecting Cisco Isdn PRI Network Modules to the Network