Samsung SP-M251, SP-M270, SP-M221 Clearing Indicator Problems, Classifica State Measures Tion

Page 41

Clearing Indicator Problems

CLASSIFICA

STATE

MEASURES

TION

 

 

 

 

 

 

The cooling fan system is not

If the symptom remains even after disconnecting and then reconnecting

Action 1

operating normally.

the power cord and turning the projector on again, contact your product

 

 

provider or our service center.

 

 

 

 

The lamp cover protecting the

Check if the screws on the side of the projector are securely tightened. If

Action 2

lamp unit is not properly closed

they are and the indicators are still lit, contact your product distributor or a

or the sensor system is not

service center.

 

 

operating normally.

 

 

 

 

Action 3

The lens cover has not opened

Open the lens cover completely.

completely.

 

 

 

 

 

 

 

The projector has changed to

If the internal temperature of the projector has increased beyond the main-

 

the Cooling mode because the

tenance limit, the projector changes to the Cooling mode before turning off

 

internal temperature of the pro-

automatically.

 

jector has increased beyond

* In Cooling mode, the fan speed is increased and the projector’s lamp is

 

the maintenance limit.

 

changed to <ECO> mode.

 

 

Action 4

 

Check whether the ventilation hole of the projector is blocked.

 

 

 

 

Check the air filter and clean if blocked.

 

 

Check whether the surrounding temperature of the projector is higher than

 

 

the standard temperature range of the projector.

 

 

Cool the projector sufficiently and operate it again.

 

 

 

 

The internal temperature of the

Check whether the ventilation hole of the projector is blocked.

 

projector has risen higher than

Check the air filter and clean if blocked.

 

the limit, and the projector has

 

Check whether the surrounding temperature of the projector is higher than

 

turned off automatically.

Action 5

the standard temperature range of the projector.

 

 

 

Cool the projector sufficiently and operate it again.

 

 

If the same problem occurs continually, contact your product distributor or

 

 

service center.

 

 

 

 

The lamp has malfunctioned

Turn the power off, wait for a sufficient amount of cooling time and then

Action 6

after power turns off abnormally

turn the power on to operate. If the same problem occurs continually, con-

or after the projector is powered

tact a Samsung service center.

 

 

on right after turning off.

 

 

 

 

This Projector uses a cooling fan system to keep the unit from overheating. Operation of the cooling fan may produce noise, This does not affect product performance and is part of normal operation.

Using

3-4

Image 41
Contents LCD Projector Table Of Contents Before You Start Using this ManualIcons used in this manual Copyright NoticeCleaning the Surface and the Lens Care and MaintenanceIcons used for safety precautions Safety PrecautionsPower Related Meaning of SignsInstallation Related Usage Related Major Safety Precautions Major Safety Precautions Package Contents Installation and ConnectionInstalling the Projector Leveling with Adjustable Feet Zoom and Focus Adjustment Screen Size and Projection Distance 528.3 Lamp Replacement Procedure Lamp ReplacementVentilation openings Replacing and Cleaning the FilterAir intake vent Icon Name Rear SideSP-M201 SP-M221 SP-M251 SP-M270 / SP-M300 PC Timing D-Sub/HDMI Supported Display ModesAV Timing Hdmi Format Resolution ScanAV Timing D-Sub AV Timing Video Connecting the Power Setting up the PC Environment Connecting with a PC and Setting up the PCInstallation and Connection Connecting with a PC Installation and Connection Configuring the Audio Settings for Your PC Connecting a PC using an HDMI/DVI cableConnecting a PC using an HDMI/DVI cable Installation and Connection Connecting an HDMI-Compatible Device Connecting an AV device using a D-Sub cable Connecting an AV device with Component output Connecting using a Video cable Connecting an External Speaker Locking the product Kensington Lock slotProduct Features UsingIcon Name Description Front, UpperInstall Button Remote ControlStatus Lamp Stand by LED IndicationsLED Indications Classifica State Measures Tion Clearing Indicator ProblemsInput Using the Screen Adjustment Menu OSD On Screen DisplayPicture Menu SUB-MENUGame mode, the text in still pictures may appear unnatural Sub modes Setup Subtitles Option Remote control Before Requesting Service TroubleshootingScreen Model SpecificationsSP-M201 / SP-M221 / SP-M251 SP-M270 SP-M300 Serial Communication Protocol RS232C Command TableCommunication Format Complies with the RS232C Standard Control Item CMD1 CMD2 CMD3 Value Command Table0X02 0x00 ~100 Brightness IRE/NOR Picture Horizontal Continuous ECO ไทย Control Item CMD1 CMD2 CMD3 Value North America Contact Samsung WorldwideLatin America EuropeCIS Middle East Asia PacificAfrica Correct disposal of batteries in this product Europe only Correct Disposal Europe only