Samsung Comprehensive Overview of SFD-321B Specifications and Timing Diagrams

Page 23

 

FLOPPY DISK DRIVE SPECIFICATION

PAGE

22

 

 

 

 

MODEL

SFD-321B

 

 

 

 

 

 

6.TIMING DIAGRAM

6.1Seek Operation Timing

DRIVE SELECT

DIRECTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FORWARD

 

 

 

 

 

 

 

 

 

 

REVERSE

 

 

 

 

 

SELECT

 

 

 

 

 

 

 

1

Min.

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

500

Min.

 

 

 

 

 

 

 

 

Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18 Min. (*1)

 

 

 

 

 

 

 

 

 

 

STEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Min.

2.8

 

Max.

 

 

 

 

 

 

 

10 Max. Min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRACK 00

6.2 Read / Write Operation Timing

 

 

 

 

 

 

 

 

650 Min.

MOTOR ON

 

 

 

 

 

 

 

 

 

600 Max.

 

 

 

 

650 Min.

 

 

 

 

 

 

DRIVE SELECT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3 Max.

READY

 

 

 

 

 

 

 

 

STEP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(*2)

DENSITY

 

 

 

 

 

 

 

 

SELECT

18 ms Min.

100

Min. (*3)

100 Min. (*3)

 

 

 

(*2)

READ DATA

0

Min.

 

 

 

 

 

 

 

ms Min.

 

 

 

 

(*2)

 

 

18

 

 

 

 

 

 

 

100 Min

(*3)

 

 

WRITE GATE

 

 

 

 

 

 

 

 

 

0

Min.

 

 

8

Max.

8 Max.

 

 

 

 

 

 

 

 

 

 

 

WRITE DATA

 

 

 

 

 

 

 

 

<Note>

(*1) Turn Around Time is 18 ms Min. when Direction is changed. (*2) 750Min. (including 100 Side Select timing)

(*3) When spindle motor speed is changed (300 rpm 360 rpm) this value is 500 ms Min.

SEMA ELECTRONICS CO.,LTD

Image 23
Contents OEM Manual SFD-321B Floppy Disk Drive SpecificationSafety Standards Packaging Description Disk Used ApplicationLOW High E M Density Standard Option PerformanceFloppy Disk Drive Specification Environmental Conditions SpecificationReliability E M SpecificationPower Supply Physical Specifications Page Page Page SFD-321B*1 Signal InterfacePower Interface Signal Interface Connector and Cable Side Connector Interface ConnectorsSignal Interface Connector Side Power Interface Connector and Cable Side Connector Power Interface ConnectorConnector Recommended Interface Circuit Signal LevelSignal Logic Input Level Output Level *1 Drive Select 0 Input SignalsType Contents Density SelectStep Density Mode Transfer Rate TypMotor On Direction SelectIndex Output SignalsWrite Gate Side SelectRead Data MFM TrackWrite Protect Disk Change / Ready Timing Diagram Safety Standards Label Description Label DescriptionSerial Number Label Marking S1ARB00001Page Page Trace Name Description Trace OptionsColor of Bezel, Button Other Options Buyer SelectionMode Selection of Bezel TypeGeneral Comment