Rotating Clamp
Ceiling
Welded Stud for
FIG. 1
Area of detail for Figures 2, 3 & 4
Tile Bridge
Max. thickness of 11⁄4"
FIG. 2
Tile Bridge
Max. thickness of 5⁄8"
FIG. 3
Max. thickness of 11⁄4"
FIG. 4
27⁄16" Min. Depth from rim of plaster ring to back of 4" Strategy speaker.
Note: Transformer equipped models require 43⁄8" depth.
FIG. 5
STRATEGY SERIES™ 4" SYSTEM INSTALLATION
Figure 1: Enclosures mount quickly using rotating clamps. Grille push-mounts with “easy-fit” welded studs.
Figure 2: Enclosure installation from below ceiling using tile bridge above. This room-side in- stallation into suspended tile utilizes rotating clamps to sandwich tile between bridge and enclosure. Max. ceiling thickness is 11⁄4".
Figure 3: Enclosure installation from above ceiling using tile bridge (new construction). Rotating clamps are used to pre-mount tile bridge to enclosure, allowing system to be posi- tioned in ceiling before tiles are set. Please note maximum ceiling thickness in this application is 5⁄8" to allow grille studs to mount into enclosure.
Figure 4: Enclosure installation from below ceiling without tile bridge. This blind-mount instal- lation method, which is most common in plaster, drywall and retrofit applications, is accom- plished by cutting an opening to size, inserting the enclosure and rotating the clamps. Max. ceiling thickness is 11⁄4".
Figure 5: Illustrates wall-mount installation using plaster ring Model FAPR-4. A minimum wall depth of 27⁄16" (from rim of the plaster ring to the back of the speaker) is required for mounting.
ARCHITECT AND ENGINEER SPECIFICATIONS
Please refer to
Specifications subject to change without notice
1601 JACK MCKAY BLVD. / ENNIS, TEXAS 75119 U.S.A. / TELEPHONE: (800)