LG Electronics RT-21FA35R/RX/V/VX service manual Specifications, Scope Requirement for Test

Page 7

SPECIFICATIONS

Note : Specification and others are subject to change without notice for improvement.

F Scope

 

 

 

F Requirement for Test

 

This specification can be applied to all the television related to

Testing for standard of each par must be followed in below

 

MC-049B Chassis.

 

 

condition

F Test and Inspection Method

 

 

1) Temperature : 20 ± 5¡C

 

 

(CST must be tested 40 ± 5¡C . Humidity : 50%)

 

1) Capacity : Follow LG electronics TV testing Standard.

2) Relative Humidity : 65 ± 10%

 

2) Another Required Standard

 

 

3) Power : Standard input Voltage (110-240V~, 50/60Hz)

 

- EMI : Following CE Standard (EN55020, EN55013)

4) Measurement must be performed after heat-run more than

 

- Safety : Following CB Standard (EN55013)

20min.

 

 

 

 

 

5) Adjusting Standard for this chassis is followed a special

 

 

 

 

 

standard.

F General Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No

Item

 

Specification

 

Remark

 

 

 

 

 

 

 

 

 

1

Receiving System

1) PAL/SECAM BG

 

For EU/ For Non EU

 

 

 

 

2) PAL/SECAM DK

 

 

 

 

 

 

3)

PAL I/I

 

 

 

 

 

 

4) NTSC M

 

 

 

 

 

 

5)

SECAM-L/LÕ

 

 

 

 

 

 

6)

NTSC 4.43(AV)

 

 

 

 

 

 

 

 

 

 

 

 

2

Receiving Channel

1)

VHF : E2 ~ E12

 

For EU/ For Non EU

 

 

 

 

 

UHF : E21 ~ E69

 

 

 

 

 

 

 

CATV : S1 ~ S20

 

 

 

 

 

 

 

HYPER : S21 ~ S41

 

 

 

 

 

 

2)

L/LÕ : B,C,D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3)

VHF : 02 ~ 13

 

NTSC-M (Multi - model)

 

 

 

 

 

UHF : 14~ 69

 

 

 

 

 

 

 

CATV : 02 ~ 71

 

 

 

 

 

 

 

 

 

 

 

3

Input Voltage

110-240V~, 50/60Hz

 

Non EU

 

 

 

 

240V~, 50Hz

 

EU

 

 

 

 

 

 

 

 

4

Market

EU,CIS, China, Asia, Africa

 

 

 

 

 

 

 

 

 

 

5

Screen Size

14Ó ~ 21Ó

 

FLAT / CONVENTIONAL

 

 

 

 

 

 

 

 

 

6

Tuning System

FVS 100Program

 

 

 

 

 

 

 

 

 

 

 

 

7

Operating Environment

1)

Temp. : 0 ~ 45 deg

 

200 PR. (OPTION)

 

 

 

 

2)

Humidity: 85% under

 

 

 

 

 

 

 

 

 

 

 

 

8

Storage Environment

1)

Temp. : -20 ~ 60 deg

 

 

 

 

 

 

2)

Humidity: 85% under

 

 

 

 

 

 

 

 

 

 

 

- 7 -

Image 7
Contents MODELRT-21FA35R/RX/V/VX MODELRT-21FA315EX/PX Contents Important Safety Notice Safety PrecautionsRemote control handset Swap SleepVCR Buttons PIPFront panel Main Power ON/OFFPOWER/STANDBY Indicator Remote Control SensorTest and Inspection Method SpecificationsGeneral Specification Scope Requirement for TestFocus adjustment Purity & Convergence adjustmentApplication Object White balance adjustment Screen voltage adjustmentDeflection setting Data Adjustment OPTION3 Function Option AdjustmentPreparation for Adjustment OPTION2 FunctionOPTION4 Function RF- Stereo Model Picture O. K / no Sound Trouble ShootingCheck B+ SCL, SDA AV Sterro / Mono Model Printed Circuit Board Component Location Guide PIP Block DiagramExploded View Descriptions Exploded View Parts ListDiode TransistorCapacitor 47UF STD 16V M FL TP5 22UF STD 16V M FL TP51UF STD 50V M FL TP5 10UF STD 25V M FL TP5Resistor Coil & InductorRWR 7W 1.0 OHM J PD 0RKZVTA001KMiscellaneous SwitchAccessories Filter & CrystalNo 3854VA0162A S1 SVC. Sheet 3854VA0162A-S Sep.,2004