NEC 5800, 120Mf manual 0BDA

Page 30

4-6 Troubleshooting

On-screen error message

Description

Cause

Action

0BD3

2nd SMBus device

A device-less answers

 

 

 

address not

to 2nd SMBus access.

 

 

 

acknowledged.

 

 

 

0BD4

2nd SMBus device

The error was detected

 

 

 

Error detected.

to 2nd SMBus access

 

 

0BD5

2nd SMBus timeout.

The timeout occurred to

 

 

 

 

2nd SMBus access.

 

 

0BD6

3rd SMBus device

A device-less answers

 

 

 

address not

to 3rd SMBus access.

 

 

 

acknowledged.

 

 

 

0BD7

3rd SMBus device

The error was detected

 

 

 

Error detected.

to 3rd SMBus access

 

 

0BD8

3rd SMBus timeout.

The timeout occurred to

 

 

 

 

3rd SMBus access.

 

 

0BD9

4th SMBus device

A device-less answers

 

 

 

address not

to 4th SMBus access.

 

 

 

acknowledged.

 

 

 

0BDA

4th SMBus device

The error was detected

 

 

 

Error detected.

to 4th SMBus access

 

 

0BDB

4th SMBus timeout.

The timeout occurred to

 

 

 

 

4th SMBus access.

 

 

0BDC

5th SMBus device

A device-less answers

 

 

 

address not

to 5th SMBus access.

 

 

 

acknowledged.

 

 

 

0BDD

5th SMBus device

The error was detected

 

 

 

Error detected.

to 5th SMBus access

 

 

0BDE

5th SMBus timeout.

The timeout occurred to

 

 

 

 

5th SMBus access.

 

 

0BE8

IPMB device address

A device-less answers

IPMB Access error

 

 

not acknowledged.

to IPMB access

 

 

0BE9

IPMB device Error

The error was detected

 

 

 

detected.

to IPMB access

 

 

0BEA

IPMB timeout.

The timeout occurred to

 

 

 

 

IPMB access.

 

 

8100

Memory Error

A memory error was

DIMM error

Replace two DIMMs.

 

detected in DIMM

detected.

 

 

 

group #1

 

 

 

8101

Memory Error

 

 

 

 

detected in DIMM

 

 

 

 

group #2

 

 

 

8102

Memory Error

 

 

 

 

detected in DIMM

 

 

 

 

group #3

 

 

 

8120

Unsupported DIMM

Unsupported DIMM

 

 

 

detected in DIMM

was detected.

 

 

 

group #1

 

 

 

8121

Unsupported DIMM

 

 

 

 

detected in DIMM

 

 

 

 

group #2

 

 

 

Image 30
Contents EXPRESS5800/120Mf Page Contents Maintenance Parts Preface Safety Indications Chapter About Warning LabelsSafety Notes GeneralPower Supply and Power Code Use Page Installation, Relocation, Storage, and Connection Cleaning and Working with Internal Devices During Operation For Proper Operation Transfer to Third Party NEC Express serverProvided software Disposal and Consumables Advice for Health Adjustment of Display Unit AnglesUser Support Overview Specifications Unit Configuration 120MfNames and Functions of Components Unit Configuration Cable Connection List Troubleshooting Troubleshooting Troubleshooting PSU Smbios Srom 0BDA Troubleshooting Error Beep Codes Post Codes Initialize Bios interrupts INT19 Troubleshooting Preventive Maintenance Preventive Maintenance Installing Internal Optional Devices Power Supply Cage Removing the Power supply unit CageInstalling the Power supply unit Cage Installing the FAN unit FAN UnitRemoving the FAN unit Installing the New Motherboard MotherboardRemoving the Motherboard Making Backup Copies of Nvram Information NEC ExpressbuilderRestoring Nvram Information Size File Name Setup Password Cenvram 120Me 856-060230-001-00 Updating SDR FW Mounting a Heat Sink on the CPURemove the screws fixing the Motherboard Installing Optional Internal Devices How to Attach the Motherboard Installing Optional Internal Devices Scsi Back Panel SCSI-B.P & SAF-TE Board Removing the SCSI-B.PInstalling the Scsi Back Panel CD-ROM Drive Removing the CD-ROM DriveFloppy Disk Drive Removing the FDDFront Bezel Removing the Front BezelFront SUB Bezel Removing the Front Sub BezelFront Panel Board Removing the Front Panel BoardOther Option Parts Rack Mount ConversionInstalling Optional Internal Devices Maintenance Parts Maintenance Parts ListMaintenance Parts About the USE of Screws Transporting the UnitPage