Extron electronic 68-1921-50 setup guide VN-Matrix 200 Setup Guide, Rear Panel Features

Page 1

VN-Matrix 200• Setup Guide

The Extron® VN-Matrix 200 Series provides real-time transmission of high resolution audio visual content across standard IP networks for live viewing, collaboration, storage, and playback.

The VN-Matrix 200 Series encodes video or graphics sources at resolutions up to HD or WUXGA, streams the video and audio over an IP network, then decodes the content back to the original source resolution. VN-Matrix applies the Extron PURE3Codec, a unique wavelet-based compression technology. The VN-Matrix 200 Series offers real-time streaming and low latency, making it

ideal for remote collaborative and interactive or control applications. It can be deployed in live event streaming and high level conferencing for specialized projects.

NOTE: For full installation, configuration, and operation details, refer to the VN-Matrix 200 User Guide, available at

www.extron.com.

Before You Connect to a Network

Before connecting each VN-Matrix to a network you must change its default network settings. On an existing network, check with the network administrator for a range of suitable IP addresses.

On a closed network, used exclusively by VN-Matrix, we recommend that you use addresses in the range 192.168.0.1 to 192.168.0.254 with a subnet mask of 255.255.255.0. The following diagram shows an example addressing scheme for a simple system comprising four VN-Matrix units:

Controller

IP Address: 192.168.0.102

IP Address: 192.168.0.101

Subnet mask: 255.255.255.0

Subnet mask: 255.255.255.0

LAN-1

LAN-1

LAN-2

LAN-2

STATUS

STATUS

VN-MATRIX 200 SERIES

VN--MATRIXIX 200 SERIESIES

RGB/DVIIOOVERIPIP

RGB/DVIIOOVERIPIP

 

TCP/IP

 

Network

IP Address: 192.168.0.103

IP Address: 192.168.0.104

Subnet mask: 255.255.255.0

Subnet mask: 255.255.255.0

LAN-1

LAN-1

LAN-2

LAN-2

STATUS

STATUS

VN-MATRIX 200 SERIES

VN-MATRIX 200 SERIES

RGB/DVI OVER IP

RGB/DVI OVER IP

VN-Matrix Controller

One VN-Matrix device in a group must be designated as the “controller.” All system configuration is achieved via a web interface that is served up by the controller. In the above example, the unit at address 192.168.0.101 is designated the controller for this group of VN-Matrix devices. Note that the controller IP value on each device is set to this address.

Setup Procedure

Follow the step-by-step instructions in the “Initial Setup” section for each VN-Matrix, then follow the “Operation” section instructions to create a simple VN-Matrix system. For more detailed information and advanced setup procedures refer to the user guide.

Rear Panel Features

 

 

 

 

e

g

j

k

 

IN

 

 

 

 

COM 1

COM 2

 

 

 

 

 

 

 

12V DC

 

 

 

 

 

 

 

REG

OUT

 

 

 

 

 

 

6A MAX

DIGITAL

I

II

PERIPH

PC

OUT DVI-I

IN DVI-I

AUDIO

 

 

 

 

 

 

 

a

b

 

c

d

f

h

i

A

B

DC power connector — The VN-Matrix 200 requires a 12 VDC regulated power supply (rated at 6 A) via this connector. A suitable power supply unit (PSU) is provided.

Digital audio connectors — Use these two female RCA connectors for input or output digital audio signals through S/PDIF coaxial cables.

1

Image 1
Contents Rear Panel Features VN-Matrix 200 Setup GuideSetup Procedure Before You Connect to a NetworkInitial Setup VN-Matrix 200 Setup Guide, cont’dOperation Start up and LoginNetwork Front Panel LED indicators Configure the VN-Matrix 200 Units as Encoders or Decoders68-1921-50 Rev. a