Operation, cont’d
Video switcher — SIS command: i&
This configuration is the same as for the
Audio switcher — SIS command: i$
Comm-Link
Control
RS-232
Control
|
|
|
|
|
|
| INPUTS |
|
|
|
|
|
|
|
| |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 11 12 13 14 | 15 16 |
|
|
|
|
| |
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 11 12 13 14 | 15 | 16 |
| CONTROL |
|
| I/O |
ENTER | PRESET VIEW | ESC | VIDEO | AUDIO | ||||||||||||
|
|
|
|
|
|
| OUTPUTS |
|
|
|
|
|
|
|
|
MAV PLUS SERIES
AV MATRIX SWITCHER | IP LINK™ |
MAV Plus 1616 A (Matrix) using MCP 1000s
This configuration is the same as for the
Audio breakaway is not available in matrix mode.
In the illustration below, the master switches video only and the slave switches audio only. In this configuration, the two units are operationally identical, even though one is a master and one is a slave. The master could have been set for audio, and the slave could have been set for video.
MCP 1000 Master | |
|
MENU | NEXT |
| MCP 1000 |
MCP 1000 Slave set for Switcher
MENU | NEXT |
| MCP 1000 |
MCP 1000M, MCP 1000S, and System 10 Plus
Output (matrix) — SIS command: i*o!
Depending on the size of the matrix switcher, the MCP 1000 can be set up for one of 64 output numbers. In output mode, an MCP 1000 acts like a switcher for a specific output number on the matrix. For example, if the MCP 1000 is set up for output 5 and panel button 3 is pressed, the matrix ties input 3 to output 5.
Preset (matrix) — SIS command: p.
A preset is a set of ties, inputs to outputs, that has been made and stored previously. Depending on the size of the matrix switcher, the MCP 1000 can be set up for presets 1 through 16, or 17 through 32. Pressing an MCP button recalls (activates) a preset in the matrix.
MENU | NEXT |
| MCP 1000 |
MCP 1000 Master set for Presets
MENU | NEXT |
| MCP 1000 |
MCP 1000 Slave set for Output 1
Next (more MCP 1000s or MKP 1000s)
Output mode and preset mode on a MAV Plus 1616 A
Slave applications (comm-link)
CAUTION | Do not connect both a Matrix 3200/6400 BME |
| and an MCP 1000M (master) unit on the same |
| |
| than one master on the same |
| Both of theses units supply voltage to the comm- |
| link ports on pins A and B. Connect these pins |
| to only one power source. This does not apply to |
| MCP 1000S (slave) units. |
A slave unit has no
Matrix 3200/6400 system, either as a single control panel or with other MCP 1000 and MKP 1000 units.
An MCP 1000S must always connect to an MCP 1000M or to a Matrix 3200/6400 BME. See "Output (matrix) — SIS command: i*o!" and "Preset (matrix) — SIS command: p.", earlier in this chapter, for two examples of slave units used with a master unit.
A slave sends signals by
Daisy-chain configuration
A