Transition Networks A-CF-01 warranty Keep TWISTED-PAIR Runs AS Short AS Possible, Yes, Singlemode

Page 2

A-CF-01

Straight Through/Crossover Cable Requirements and Pin Specifications

2 kilometers - multimode

20 kilometers - singlemode

<100 meters

25 Mb/s or 155 Mb/s ATM Switch

crossover

Fileserver

<100 meters

straight-through

Be certain that the twisted-pair cable is configured

correctly (straight through or crossover) for site. Cable connections between an ATM switch and the media converter must be configured as straight through. Cable connections between the media converter and a NIC must be configured as crossover.

 

Straight Through Cable

 

 

 

 

 

 

 

Twisted

 

 

1

 

 

1

Pair #1

 

 

2

 

2

Twisted

 

 

7

 

 

7

Pair #2

 

 

8

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

Connectors for unlike devices

Twisted Pair #1

Twisted Pair #2

Crossover Cable

11

22

77

88

Connectors for like devices

The two active pairs in an ATM network are pins 1 & 2 and pins 7 & 8. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.

Installation Notes

KEEP TWISTED-PAIR RUNS AS SHORT AS POSSIBLE.

Connect the power supply cable to the media converter BEFORE connecting to the outlet.

Install unit with PSU provided. (Output 9 VDC regulated, 500 mA).

Troubleshooting the Media Converter

If the ATM media converter fails, determine the answers to the following questions:

1.Is the power LED on the media converter illuminated?

NO

Is the power adapter the proper type of voltage and cycle frequency for your AC outlet? NOTE: Refer to the “Power Supply Requirements” on the back page.

Is the power adapter properly installed in the media converter and in the outlet?

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 2.

2.Is the TX Activity LED illuminated?

NO

Check UTP cables for proper connection and pin assignment. (See above.)

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Proceed to step 3.

3.Is the Fiber Activity LED illuminated?

NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on the other 100BASE-FX device.

Refer to Tech Tips available at: http://www.transition.com

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

YES

Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.

ATM CABLE SPECIFICATIONS

The physical characteristics of the media cable must meet or exceed the specifications: ATM UNI 3.1 #AF-PHY-0015

Maximum number of media converters in series: 2

COPPER CABLE SPECIFICATIONS

Category 5 wire or better is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.

Category 5:

 

 

Gauge

24 to 22 AWG

 

Attenuation

20 dB/1000’ @ 10 MHz

Impedance

100 ±10% @ 10 MHz

Maximum Cable Distance:

100 meters (330 feet)

FIBER CABLE SPECIFICATIONS

 

 

SINGLEMODE

 

 

Fiber Optic Cable Recommended:

9 µm singlemode fiber

Fiber Optic Transmitter Power:

min: -15.0 dBm

max: -8.0 dBm

Fiber Optic Receiver Sensitivity:

min: -31.0 dBm

max: -8.0 dBm

Wavelength:

1300nM

 

Bit error rate:

10-9

 

Maximum Cable Distance:

20 kilometers

 

MULTIMODE

 

 

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber

 

85 / 125 µm multimode fiber

 

50 / 125 µm multimode fiber

Fiber Optic Transmitter Power:

min: -19.0 dBm

max: -14.0 dBm

Fiber Optic Receiver Sensitivity:

min: -30.0 dBm

max: -14.0 dBm

Wavelength:

1300nM

 

Bit error rate:

10-9

 

Image 2
Contents Activity Copper PwrActivity Fiber Singlemode Keep TWISTED-PAIR Runs AS Short AS PossibleYES Multimode