7.4 Record Setting

When entering the main menu, select Record Setting and press the <ENTER>

key to enter the menu

Press <←><→> key to move the cursor

Press <><> key to make changes

Press <EXIT> key to return to the previous page.

Press <STOP> key to skip over the main menu (Image display).

Quality

RECORD SETTING

QUALITY

HIGH

RESOLUTION

720X240

REC RATE

10 FPS

DISK FULL

OVERWRITE

AUDIO IN

OFF

RECORD TIME

 

TOTAL TIME

: 53HR

REMAINING TIME: 33HR

Three choices to select from:

HighLarge file capacity and high image quality display.

MidMedium file capacity and medium image quality display.

LowSmall file capacity and low image quality display.

Resolution720 × 240 or 360 × 240.

REC RatePress <><> key to adjust the recording rate.

When Quality setting is HIGH:720x2401~6 FPS

360x2401~9 FPS

When Quality setting is Mid or Low:720x2401~10 FPS

360x2401~15FPS

Disk Full

OverwriteWhen the disk is full it starts to overwrite the information

from the beginning

14

Image 15
Contents Speco Technologies New Highway Amityville. NY Tel Fax DVR-X1Contents Features GBstandard or 80 GB optional SpecificationMjpeg HDDRear panel Power Supply: 12V DC,4A InstallationREC :Under normal mode, press this key to enter record modeFunction Key Description Front PanelPage Play Mode Playback ModeSearch Year、Month:Day、Hour、Minute: Page Recording Mode Main Menu Menu Set UpEnter Main Menu System StatusDate / Time Date / TimeLeft TOP Right TOP Left Bottom Right Bottom Disk Full: Record SettingRecord Setting Quality:Record Time: Audio In:Begin / END: Record ModeRecord Mode REC:End : Ending time for recording SEN Sensor Sensitivity:1~ 5 Adjustable No → Normal-open sensor TTL level input Sensor Type: NC → Normal-close sensor TTL level inputAlarm Output Video Loss Alarm Engineering SetupEngineering Setup Camera Title Setup Set PasswordCamera Title Setup SET PasswordHard Disk Erasing Check PasswordVideo Quality Hard Disk ErasingLoad Factory Default Load DefaultColor Bar System Installation Diagram