5.2.2Toll Restriction (TRS) Features

Toll Restriction (TRS) can prohibit certain extension users from making unauthorised outside (CO) line calls. Every extension is assigned to one of 5 classes of service (COSs) for each time service mode (TRS-COS—Day/Night/Lunch[601-603]);COS 1 grants the highest level of authorisation, allowing all outside (CO) line calls to be made, and COS 5 grants the lowest level of authorisation. COSs 2 through 5 are used to restrict calls with a combination of preprogrammed Denied Code Table (TRS—COS2-5 Denied Code [302-305])and Exception Code Table (TRS—Exception Code [306]).

Applicable tables by COS

The Denied Code Tables and Exception Code Tables that apply to each COS are listed below.

COS No.

Denied Code Tables

Exception Code Tables

 

 

 

1

No restriction.

No restriction.

(Not Programmable)

(Not Programmable)

 

 

 

 

 

20 denied codes programmed in [302].

80 exception codes (code numbers 01–

2

(Table for Class 2)

80) programmed in [306].

 

 

(Tables for Classes 2 through 5)

 

 

 

 

40 denied codes programmed in [302]

60 exceptions codes (code numbers 01–

3

and [303].

60) programmed in [306].

 

(Tables for Classes 2 and 3)

(Tables for Classes 3 through 5 )

 

 

 

 

60 denied codes programmed in [302]

40 exception codes (code numbers 01–

4

through [304].

40) programmed in [306].

 

(Tables for Classes 2 through 4)

(Tables for Classes 4 and 5)

 

 

 

 

80 denied codes programmed in [302]

20 exception codes (code numbers 01–

5

through [305].

20) programmed in [306].

 

(Tables for Classes 2 through 5)

(Table for Class 5)

 

 

 

TRS-COS—Day/Night/Lunch [601-603]

 

 

 

 

NEXT or

PREV

 

 

 

 

6

X

 

To

continue

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEXT

extension jack no.

COS no. STORE

END

 

(0103)

 

(0108/ )

(15)

 

01:for day

02:for night

03:for lunch

To continue

SELECT

30

Getting Started

Image 30
Contents Getting Started Advanced Hybrid SystemOptional Service Cards System Components Table Model Description Main UnitProprietary Equipment Important Safety Instructions For users in New Zealand only For users in Australia onlyFor users in Taiwan only For users in Finland, Norway and Sweden only Precautions for Users in the United Kingdom Getting Started Table of Contents Necessary tools not supplied Check the package contentsUnpacking Diameter of cable Maximum length of cable Mm to ø 0.6 mmSystem Connection Diagram Outside CO LineConnecting Outside CO Lines Opening CoversConnecting Extensions TEA308 TEB308Securing the Cables Closing Covers Wall Mounting Mounting on a Wooden WallMounting on a Concrete or Mortar Wall Connecting Frame Earth Connect the frame of the PBX to earthGetting Started Starting the Advanced Hybrid System Starting the Advanced Hybrid SystemGetting Started Operating System PC ProgrammingSystem Requirements HardwareProgramming Instructions Required TelephoneFixed Button KX-T7730/KX-T7735 Function Programming Procedures Entering System Programming ModeProgramming No Alphabet mode/ Numeral mode Cyrillic alphabet mode for RU Russia/UA Ukraine model Example of Entering CharactersSystem Password Date & TimeSystem Speed Dialling Number Operator Assignment Extension NumberAutomatic Line Access Dial ModeSystem Speed Dialling Name Country Extension NameExtension Name in Cyrillic 01 …08TRS-COS-Day/Night/Lunch Applicable tables by COSCOS No Denied Code Tables Exception Code Tables TRS-COS 2-5 Denied Code TRS-Exception CodeGetting Started Getting Started Getting Started Template for Wall Mounting Trademarks Copyright PSQX3553ZA KK0405HS0