Panasonic TH-50PH10UK, TH-58PH10UK, TH-37PH10UK, TH-42PH10UK manual Normalization

Page 42

Options Adjustments

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

3/3

 

 

 

 

 

 

 

 

 

Slot power

Off

 

 

 

 

 

 

 

V. lnstallation

Off

 

 

 

 

 

 

 

Rotate

Off

 

 

 

 

 

 

 

Serial Slot Select

Slot1

 

 

 

 

 

 

 

 

 

 

 

 

Item

Effect

 

 

Adjustments

 

 

 

 

 

 

Off

Auto

On

 

 

 

 

 

 

Off:

Power is not transmitted to the slot power.

 

 

 

Slot Power

 

 

Auto: Power is transmitted to the slot power only when main power is on.

 

 

 

 

 

On:

Power is transmitted to the slot power when main power is on or in the standby state.

 

 

 

 

 

 

 

 

 

 

 

 

Note: In some cases, power is transmitted to the slot power when main power is on or in the standby

 

 

 

 

state regardless of the slot power setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off:

Sets fan to the horizontal installation mode.

 

 

 

 

 

 

On:

Sets fan to the vertical installation mode.

 

 

 

V.Installation

 

 

Notes:

 

 

 

 

 

 

 

Off

On

• This functions when display is turned on.

 

 

 

 

 

 

 

 

 

 

• This mode is available for TH-42PH10UK, TH-50PH10UK and TH-58PH10UK.

 

 

 

 

 

 

• Turn up the power switch for the upward direction when you set Display vertically.

 

 

 

 

 

 

 

 

 

 

 

 

 

Rotate

 

 

Off:

Does not rotate the image.

 

 

 

Off

On

On:

Rotates the image 180 degrees.

 

 

 

 

 

 

 

 

 

 

Slot1

Slot2

Slot3

 

 

 

Serial Slot

 

 

Selects the slot which communicates serial.

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

Select

 

 

 

 

 

 

 

 

 

 

 

• The setting of an external command can be set only from the fixed serial terminal (see page 11)

 

 

 

 

 

 

• Slot3 cannot be selected on TH-37PH10UK.

 

 

 

Normalization

When both main unit buttons and remote control are disabled due to the “Button lock”, “Remocon User level” or “Remote ID” adjustments, set all the values “Off” so that all the buttons are enabled again.

Press the

button on main unit together with

button on the remote control and hold for more than 5 seconds. The

“SHIPPING” menu is displayed and the lock is released when it disappears.

42

Image 42
Contents Operating Instructions Manual de instrucciones English EspañolModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents FCC Statement Trademark CreditsSafety Precautions When using the Plasma DisplaySetup MaintenanceSafety Precautions / Maintenance AC Power Supply CordAccessories Accessories SuppliedRemote Control Batteries Connections SpeakersAC cord fixing Signal Names for Mini D-sub 15P Connector PC Input Terminals connectionConnections Communication parameters CommandSerial Terminals connection Basic format for control dataRGB signal R, G, B AV & Component / RGB connectionConnecting the plug to the Wall Outlet Power on / OFFConnecting the AC cord plug to the Plasma Display Fix the AC cord plug securely to the Plasma Display. seeBasic Controls Basic Controls VA N C E D Settings On-Screen Menu DisplaysTime / Power OFF Time On Time / Power OFFOn-Screen Menu Displays Selecting the On-Screen Menu Language Selecting the input signalInitial selections INPUT1A INPUT1B INPUT2 PCPanasonic Auto Aspect ControlsNormal Zoom Full During Multi PIP OperationsRGB/PC in mode Adjusting POS. /SIZEClock Phase Eliminate the flickering and distortionMulti PIP Sub screen Main screen Advanced PIPOne screen Advanced PIP Press to exit from Options menu 1280x768@60Hz DVIAdvanced Settings OFF Picture AdjustmentsAdvanced Settings on Standard Cinema DynamicEffect Adjustments Advanced SettingsPicture Adjustments Effect DetailsSound Adjustment MutePosition Digital ZoomDisplay the operation guide Select the magnification required for the enlarged displayPresent Time Setup Press to set up DAY or Present Time of DAYButton Forward SET UP Timer Display the SET UP Timer Screen Press to selectPower on Time / Power OFF Time Screensaver For preventing image retention Mode selectionStart setting Negative / Scroll selectionSetup of Screensaver Time Reduces screen image retentionScreensaver For preventing image retention Side BAR Adjust OFF Dark MID BrightPress to exit from Screensaver Reduces power consumption Customizing the Input labelsAddition sign Selected Input SET UP for Multi Display How to setup Multi DisplaySET UP for Multi Display Display Number locations for each arrangement ExamplesID remote control button operation Seam Hides Video SettingID Remote Control Function ID Cancellation3D Y/C Filter For Ntsc AV images SET UP for Input SignalsComponent / RGB in Select SelectSET UP for Input Signals Color System / Panasonic AutoPulldown / Video NR Refresh Rate Setting RGB sync signalSync FREQ. kHz / V-FREQ. HzOptions Adjustments Options1/3Options Adjustments Off Initial VOL Sets normal volume LevelEnable Normalization Weekly Command Timer Time Set the time to execute a command program Press to select a command numberPress to select Time / Command Press to set each itemShipping condition Troubleshooting Plasma Display panelPAL60 VIDEO/COMPONENT/RGB/PC input signalsVideo input RGBCommand list of Weekly Command Timer Specifications TH-37PH10UK TH-42PH10UKSpecifications TH-50PH10UK TH-58PH10UKLimits and Exclusions Limited Warranty Statement Executive Office Customer’s RecordPanasonic Broadcast & Television Systems Company Panasonic Canada Inc
Related manuals
Manual 53 pages 63.69 Kb