EMC FC, ATA manual Standards Certification and Compliance, Fibre Channel Related Standards

Page 62

Technical Specifications

Standards Certification and Compliance

Rackmount disk enclosures are tested and certified for compliance with the international environmental and safety specifications listed below and marked to indicate such compliance and certification as required.

Standard

Description

 

 

CSA 22.2 No. 950

 

 

Safety of Information Technology Equipment including Electrical

EN 60950

Business Equipment

 

UL 1950

 

 

 

CE Mark

European EMC Directive & Low Voltage Directive Requirements

 

 

EMI Standards

Standard

Description

 

 

FCC Part 15

Class A, Radio Frequency Device Requirements

 

 

ICES-003

Class A, Interference-Causing Equipments Standard - Digital

 

Apparatus

 

 

CE Mark

European EMC Directive & Low Voltage Directive Requirements.

 

 

VCCI

Class A, Voluntary Control Council for Interference

 

 

AS/NZS 3548

Class A, Electromagnetic Interference - Limits & Methods of

 

Measurement of ITE

 

 

CNS13438

BSMI EMC Requirements

 

 

Fibre Channel Related Standards

Standard

Description

 

 

Fibre Channel

Physical and signaling interface, FC-PI, draft Rev. 13

 

 

Fibre Channel

Arbitrated Loop (FC-AL), Revision 4.5

 

 

Fibre Channel

Private Loop Direct Attach (PLDA), Revision 2.1

 

 

In some cases, the DAE2 uses functions from later revisions of specifications.

A-4

2-Gigabit Disk-Array Enclosure (DAE2) Hardware Reference

Image 62 Contents
EMC 2-Gigabit Disk-Array Enclosure DAE2 FC and ATA ModelsCopyright 2002, 2003 EMC Corporation. All rights reserved Regulatory Notices Gigabit Disk-Array Enclosure DAE2 Hardware Reference Contents Appendix a Technical Specifications Chapter Servicing a DAE2Figures Figures Preface Related Documentation Conventions Used in This Guide All Storage Systems on the Operations menu Sales and Customer Service Contacts Xiii Replacing the Lithium Battery About DAE2 Disk Enclosures Introduction DAE2Introduction LED 3Disk Enclosure Rear View Midplane Front BezelLink Control Cards LCCs Monitoring Disk Enclosure Status in ChapterDrive Carrier Disk ModulesDisk Drives Power Supply/System Cooling Modules 8Power Supply/System Cooling ModuleGigabit Disk-Array Enclosure DAE2 Hardware Reference Installing a DAE2 Cabling RequirementsSite Requirements RequirementsInstalling a Disk Enclosure in a Cabinet RecommendationsSetting Up an Installed Disk Enclosure Address +Switch 2Plugging in the ac Line Cord DAE2 PRI SPE LCC B Powerup and Initialization Binding Disk Modules into RAID Groups Servicing a DAE2 Monitoring Disk Enclosure Status Describes the LEDs visible from the front of the DAE2Light Quantity Color Meaning Shows the status LEDs for the power/cooling modules Shows the status LEDs for the link control cards Handling FRUs An ESD Kit Procedures WithoutEmergency Precautions When Removing, Installing, or Storing FRUs Replacing or Adding a Disk Module Unlocking and Removing the Front Bezel 5Unlocking and Removing the Front BezelRemoving a Disk Filler Module Removing a Disk ModuleInstalling a Disk or Filler Module 7Removing a Disk Module FC Disk Carrier Shown8Installing a Disk or Filler Module FC Disk Carrier Shown Installing and Locking the Front Bezel 9Installing and Locking the Front BezelReplacing an LCC Module Removing an LCCInstalling an LCC 11Removing an LCC12Installing an LCC Remove and store the ESD wristband 14Connecting Disk Enclosures Together with Copper Cable Replacing a Power Supply/System Cooling Module 16Removing a Power Supply/System Cooling Module 18Plugging in the Power Cord and Turning on Power Technical Specifications Enclosure Specifications Ac PowerLCC FC-AL Interface Size and WeightDrive Type Standards Certification and Compliance Fibre Channel Related StandardsOperating Limits Shipping and Storage RequirementsGigabit Disk-Array Enclosure DAE2 Hardware Reference Index LCC Gigabit Disk-Array Enclosure DAE2 Hardware Reference Gigabit Disk-Array Enclosure DAE2 Hardware Reference