SETTING

Power management

This function turns Projection Lamp off when this projector detects signal interruption and is not used for a certain period in order to reduce power consumption and maintain the Lamp-life. (This projector is shipped with this function ON.)

Power Management function operates to turn Projection Lamp off when the input signal is interrupted and any button is not pressed over 5 minutes. This function operates as follows;

1.When any input signal is interrupted, “No signal” and the counting down display appears (for 5 minutes).

2.When Projection Lamp turned off, READY Indicator turns off. Cooling Fans operate and Projection Lamp is turned off for 90 seconds. (During this "Cooling Down" period, projector cannot be turned on.)

3.When Projection Lamp has cooled down, READY Indicator flashes and Projection Lamp can be turned on again (Power Management mode).

In this Power Management mode, Projection Lamp is automatically turned on when the input signal connected or projector is operated with any button on Top Control or on Remote Control Unit again.

Remote control

This projector has two different remote control codes; the factory-set normal code (Code 1) and the secondary code (Code 2). This switching function prevents remote control operation mixture (jam) when operating several projectors or video equipment together.

When operating projector in “Code 2,” both projector and Remote Control Unit must be switched to “Code 2.”

To change the code of Projector;

Set Remote control in the SETTING MENU to “Code 2.”

To change the code of the Remote Control Unit;

Press both MENU and IMAGE buttons on Remote Control Unit together for over 10 seconds.

After changing the code, make sure Remote Control operates properly.

To return to the normal code (Code 1), operate both projector and Remote Control in the ways above again.

NOTE : When battery of Remote Control Unit is replaced, the remote control code automatically returns to the normal code (Code 1).

Lamp counter reset

This function is used to reset Lamp Replace Counter. When replacing Projection Lamp, reset Lamp Replace Counter by using this function. Refer to page 38 for operation.

Time left until Lamp off.

Move the pointer to Lamp counter reset and then press SELECT button. The message “Lamp replace counter reset?” is displayed.

36

Image 36
Contents Model LC-XM2 To the Owner Safety Instructions Voor de klanten in NederlandCompliances Federal Communication Commission NoticeTable of Contents Features and Design Compact Design One-Touch Auto PC AdjustmentPreparation Name of Each Part of ProjectorHOT AIR Exhausted SETTING-UP Projector Connecting AC Power CordFor Continental Europe Adjustable Feet Preparation Positioning ProjectorRoom Light Preparation Moving Projector Connecting Projector USB Connector Series BTerminals of Projector ComputerConnecting to Computer Terminals ProjectorConnecting to Video Equipment Audio VideoOperation of Remote Control Before OperationRemote Control Battery Installation BatteryBefore Operation Operating Range TOP Controls and Indicators Lamp IndicatorHOW to Operate ON-SCREEN Menu Operating ON-SCREEN MenuFlow of ON-SCREEN Menu Operation Before Operation Menu BAR Guide WindowBasic Operation Turning on / OFF ProjectorTurning on Projector Turning OFF ProjectorAdjusting Screen Zoom AdjustmentFocus Adjustment Keystone AdjustmentSound Adjustment Timer FunctionBasic Operation No Show Function Direct OperationComputer Input Selecting Input SourceSelecting Computer System Select Computer System ManuallyComputer Input Compatible Computer Specifications ResolutionFreq KHzPC Adjustment Auto PC AdjustmentPC Adjust Menu Auto PC AdjComputer Input Manual PC Adjustment Display area Display area HFull screen Picture Image Adjustment Image Level Select DirectImage Level Select Menu Image Select MenuComputer Input Image Level Adjustment Image Adjust MenuPicture Screen Adjustment Screen MenuVideo Input Selecting Video System AutoAV System Menu Video or S-VIDEO AV System Menu Component VideoCinema Video Input Image Level Adjustment Provides image at a normal video aspect ratio of 4 Setting Setting MenuSetting Menu To change the code of the Remote Control Unit Power managementRemote control Lamp counter resetMaintenance AIR Filter Care and CleaningCleaning Projection Lens AppendixAppendix Lamp Replacement Lamp Replace CounterTroubleshooting Remote Control Unit Does not workOptional Parts Appendix Configurations of the Terminals Control Port ConnectorUSB Connector Series B Computer Input Terminal AnalogPage Key to better communications Canada