7. Answer
(a)Normal message
Answer
Header | 0x70 | Normal answer header |
|
|
|
Category | 0xXX | Code table |
|
|
|
Code table (7-a)
| Normal code |
|
|
|
|
0x00 | Completed | Normal response. |
|
|
|
0x01 | Limit over | The packet was received normally, but the data value was over the upper |
|
| limit. |
|
| Forcedly the monitor adjusted the data to maximum value. |
|
|
|
0x02 | Limit under | The packet was received normally, but the data value was under the lower |
|
| limit. |
|
| Forcedly the monitor adjusted the data to minimum value. |
|
|
|
0x03 | Command cancelled | The packet was received normally, but the command was cancelled because |
|
| the function was not in adjustable mode, such as a function displayed as “— |
|
| |
|
|
|
0x04 | Command all enable | The packet was received normally. |
|
| The command function is all enable. |
|
|
|
0x05 | Fail | The packet was received normally, but the command was cancelled . |
|
| Please retry. |
|
|
|
(b)Error message
Answer
Header | 0xE0 | Error answer header |
|
|
|
Category | 0xXX | Code table |
|
|
|
Code table (7-b)
| Normal code |
|
|
|
|
0x00 | No function error | Packet header,category or function codes do not exist in this protocol. |
|
|
|
0x02 | Data number error | The data value in “Data num” area of received packet was different from the |
|
| function’s own data number. |
|
|
|
0x06 | Mode error | The monitor is already in the service mode via remote commander |
|
| operation. |
|
| (The service mode through IR remote has priority over the serial remote |
|
| command. ) |
|
|
|
0x07 | Time out | Packet communication are interrupted by some error, and did not return to |
|
| normal communication within 2 seconds. |