Kodak SO-050, 2403 manual Kodak Versamat Chemicals. Type a Model

Page 4

KODAK VERSAMAT 641 Chemicals, Model 11

Machine

1 Developer Rack

2 Developer Racks

Speed

Average

ISO A

D-min

Average

ISO A

D-min

(fpm)

Gamma

Gamma

 

 

 

 

 

 

 

 

 

85° F (29.5° C)

 

 

 

 

 

 

 

 

 

5

0.80

400

0.15

1.15

640

0.17

 

 

 

 

 

 

 

10

0.55

160

0.14

0.85

400

0.15

 

 

 

 

 

 

 

15

0.65

250

0.34

 

 

 

 

 

 

 

Fixing: Adequate fixing is obtained at machine speeds up to and including 10 feet per minute.

Washing: LE-100 keeping quality is obtained at process machine speeds up to and including 5 feet per minute. (LE = Life Expectancy)

Drying: Adequate drying is obtained at machine speeds up to and including 20 feet per minute.

KODAK VERSAMAT Chemicals, Type A, Model 11

Machine

1 Developer Rack

 

2 Developer Racks

Speed

Average

ISO A

D-min

 

Average

ISO A

D-min

(fpm)

 

Gamma

 

 

 

Gamma

 

 

 

 

90° F (32° C)

 

 

 

 

 

 

 

 

 

 

 

5

2.05

1000

0.16

 

 

 

 

 

 

 

 

 

10

1.10

500

0.13

 

1.35

800

0.15

 

 

 

 

 

 

 

 

15

0.95

320

0.13

 

1.00

500

0.14

 

 

 

 

 

 

 

 

20

0.85

250

0.14

 

0.90

400

0.14

 

 

 

 

 

 

 

 

Fixing: Adequate fixing is obtained at machine speeds up to and including 10 feet per minute.

Washing: LE-10 keeping quality is obtained at machine speeds up to and including 8 feet per minute. (LE = Life Expectancy)

Drying: Adequate drying is obtained at machine speeds up to and including 12 feet per minute.

Processing Sequence

KODAK VERSAMAT Processor, Model 1140

 

 

 

(all recommended chemicals)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Processing

No. of

 

Path

 

Temperature

Step

 

Racks

 

Length

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Develop

 

1 or 2

 

1.2 or 2.4 m

 

99 or 104 ±

0.5° F

 

 

(4 or 8 ft)

 

(37 or

40 ±

0.3° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fix

 

3

 

3.6 m

 

99 or 104° F

 

 

 

(12 ft)

 

(37 or 40° C), nominal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wash

 

2

 

2.4 m

 

2 to 6° F (1 to 3° C) below

 

 

(8 ft)

 

developer temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dry

 

 

2.4 m

 

Up to 149° F (65° C)

 

 

(8 ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensitometric Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KODAK VERSAMAT 885 Chemicals, Model 1140

 

 

 

 

 

 

 

 

 

Machine

 

1 Developer Rack

2 Developer Racks

Speed

Average

ISO A

D-min

Average

ISO A

 

D-min

(fpm)

 

Gamma

 

 

 

 

Gamma

 

 

 

 

 

 

 

 

 

99°

F (37° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

0.90

640

0.21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

0.65

320

0.16

 

1.00

640

 

 

0.24

 

 

 

 

 

 

 

 

 

 

30

0.45

200

0.12

 

0.80

500

 

 

0.19

 

 

 

 

 

 

 

 

 

 

40

0.35

125

0.14

 

0.70

400

 

 

0.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

104

° F (40° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

1.00

640

0.23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

0.70

400

0.16

 

1.15

640

 

 

0.22

 

 

 

 

 

 

 

 

 

 

30

0.50

250

0.15

 

0.95

640

 

 

0.25

 

 

 

 

 

 

 

 

 

 

40

0.45

200

0.13

 

0.80

500

 

 

0.21

 

 

 

 

 

 

 

 

 

 

 

 

 

KODAK VERSAMAT 641 Chemicals, Model 1140

 

 

 

 

 

 

 

Machine

 

1 Developer Rack

2 Developer Racks

Speed

Average

ISO A

D-min

Average

ISO A

 

 

D-min

(fpm)

Gamma

Gamma

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

99° F (37° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

0.80

400

0.17

 

1.15

640

 

 

0.19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

104° F (40° C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

0.85

320

0.16

 

1.30

800

 

 

0.21

 

 

 

 

 

 

 

 

 

 

20

0.55

160

0.22

 

0.90

500

 

 

0.21

 

 

 

 

 

 

 

 

 

 

 

 

 

KODAK VERSAMAT Chemicals. Type A; Model 1140

This is not a primary processing recommendation, although satisfactory results can be obtained at processor speeds up to 10 feet per minute. Refer to the processing conditions and sensitometric data for the KODAK VERSAMAT Processor, Model 11, above.

4

KODAK TRI-X AEROGRAPHIC Film 2403 KODAK TRI-X AERECON Film SO-050 AS-24

Image 4
Contents Weight ApplicationsBase Total Film ThicknessImage Structure ExposureStorage Processing ChemicalsReplenishment Rates Processing SequenceKodak Versamat Chemicals. Type a Model Dimensional Stability Temporary Dimensional ChangesPermanent Dimensional Changes Rewind or Spiral Reel ProcessingSize Data and Ordering Information CurvesLog Wavelength nmCharacterisitc Curves ISO a vs. Machine SpeedISO a Vs. Gamma Gamma vs. Machine SpeedEastman Kodak Company ROCHESTER, NY TI0078