TP-170V 
he Crown® 
allows amplifiers without direct 70V or 100V output capability to drive distributed speaker systems designed to operate at those voltages.
The 
For more details about the Crown 
Specifications
Output connectors: One 
Frequency Response: +/- 0.5 dB (20 Hz to 20 kHz).
Insertion (Core) Loss: 0.41 dB max (70VAC at
50 Hz).
Dimensions:
19 in (48.3 cm) wide (including hinge)
7.23in (18.4 cm) high
1.45in (3.7 cm) deep.
Weight: 12.75 lbs (5.78 kg).
Features
• Four autoformers per panel provide four channels of impedance matching for 
•Provides 100V output in Dual mode when used with CTs 600, CTs 1200, CTs 4200 and CTs 8200 ampli- fiers
•Allows amplifiers without direct 
•Convenient hinged rack mounting allows easy access to connections
Installing the TP-170V 
CAUTION: Before you begin, make sure your amplifier is disconnected from the power source, with the power switch in the “off” position and all level controls turned com- pletely down (counterclockwise).
Use a standard 
Connect the Grounding Strap
Connect the 
CAUTION: Do not remove the grounding strap or leave it unconnected.
Choose Output Wire and Connectors
Crown recommends using professionally con- structed, high quality, two- or 
CAUTION: Use insulated terminal forks to pre- vent shorting against the 
To connect 
Wire Your System
Refer to the chart in Figure 1 to determine the proper transformer tap to use, based on the rated output power of your amplifier and the desired 
CAUTION: Never use shielded cable for output wiring.