3.2.3. WIDEVINE key Inspection
- Confirm key input data at the "IN START" MENU Mode.
3.3. LAN PORT INSPECTION(PING TEST)
Connect SET → LAN port == PC → LAN Port
SET PC
3.3.1. Equipment setting
(1)Play the LAN Port Test PROGRAM.
(2)Input IP set up for an inspection to Test Program. *IP Number : 12.12.2.2
3.3.2. LAN PORT inspection(PING TEST)
(1)Play the LAN Port Test Program.
(2)Connect each other LAN Port Jack.
(3)Play Test (F9) button and confirm OK Message.
(4)Remove LAN cable.
3.4. Model name & Serial number Download
3.4.1. Model name & Serial number D/L
▪Press
▪Connect
▪Write Serial number by use USB port.
▪Must check the serial number at Instart menu.
3.4.2. Method & notice
(1)Serial number D/L is using of scan equipment.
(2)Setting of scan equipment operated by Manufacturing Technology Group.
(3)Serial number D/L must be conformed when it is produced in production line, because serial number D/L is mandatory by
*Manual Download (Model Name and Serial Number)
If the TV set is downloaded by OTA or service man, sometimes model name or serial number is initialized.(Not always)
It is impossible to download by bar code scan, so It need Manual download.
1)Press the "Instart" key of Adjustment remote control.
2)Go to the menu "7.Model Number D/L" like below photo.
3)Input the Factory model name(ex
4)Check the model name Instart menu. → Factory name displayed. (ex
5)Check the Diagnostics.(DTV country only) → Buyer model displayed. (ex
3.5.CI+ Key checking method
- Check the Section 3.1
Check whether the key was downloaded or not at ‘In Start’ menu. (Refer to below).
=> Check the Download to CI+ Key value in LGset.
Copyright © | LG Electronics. Inc. All rights reserved. | - 14 - | LGE Internal Use Only |
Only for training and service purposes |
|
|