Peerless Industries SF 630-S, SF 630P-S manual Installation to Solid Concrete or Cinder Block

Page 5

Installation to Solid Concrete or Cinder Block

WARNING

When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" (35 mm) of actual concrete thickness in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" (25 mm) minimum from the side of the block. Cinder block must meet ASTM C-90 specifications. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components.

1

Make sure that wall plate (A) is level, use it as a

template to mark two mounting holes. Drill two 5/16"

(8 mm) dia. holes to a minimum depth of 2.5"

(64 mm). Insert anchors (H) in holes flush with wall as shown (right). Place wall plate over anchors and secure with two #14 x 2.5" screws (G). Level, then tighten all fasteners.

WARNING

Tighten screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage screws, greatly reducing their holding power.

Never tighten in excess of 80 in. • lb (9 N.M.).

Always attach concrete expansion anchors directly to load-bearing concrete.

Never attach concrete expansion anchors to concrete covered with plaster, drywall, or other finishing material. If mounting to concrete surfaces covered with a finishing surface is unavoidable (not evaluated by UL), the finishing surface must be counterbored as shown below. Be sure concrete anchors do not pull away from concrete when tightening screws. If plaster/drywall is thicker than 5/8" (16 mm), custom fasteners must be supplied by installer (not evaluated by UL).

VIEW

 

INCORRECT

CORRECT

wall

concrete

wall

concrete

 

 

 

plate

 

 

plate

 

 

CUTAWAY

 

 

 

 

drywall

 

drywall

 

 

plaster/

 

plaster/

1

concrete

surface

H

Drill holes and insert anchors (H).

2

A

 

 

G

H

Place plate (A) over anchors (H) and secure with screws (G).

3

Tighten all fasteners.

SOLID

CINDER BLOCK

CONCRETE

H

A

G

5 of 23

ISSUED: 04-18-05 SHEET #: 201-9427-7 04-20-10

Image 5
Contents Features Table of Contents Tools Needed for AssemblyE F G H Installation to Single Wood Stud Wall View Incorrect Correct Installation to Solid Concrete or Cinder BlockFor Vesa 100 Mounting Pattern For Vesa 75 Mounting PatternDetail Installing and Removing Flat Panel ScreenCaracterísticas Construcción DE LA Pared Accesorios Necesarios Herramientas necesarias para el ensamblajeLista de Piezas Advertencia 12 de Taje Vesa EN EL Caso DE LA Configuración DE MONEN EL Caso DE LA Configuración DE MON- Taje Vesa Instalación y desinstalación de la pantalla plana PrecauciónCapacité de charge maximale établie par l’UL 80 lb 36.3 kg CaractéristiquesType DE MUR Pièces DE Fixation Requises Outils nécessaires au montageListe des pièces Installation sur un mur à montant en bois simple 19 sur Configuration DE Montage Vesa Détail Montage et démontage d’un écran platLimited FIVE-YEAR Warranty Garantía Limitada DE Cinco Años