Icom instruction manual Cable connections, IMPORTANT!- AT-140

Page 8

2 INSTALLATIONS

Cable connections

qConnect the coaxial cable and the control cable to the AT-140 as illustrated below.

wCover both the antenna and the control cable con- nectors with rubber vulcanizing tape and fix it with a vinyl tape to prevent water seeping into the con- nector.

rConnect the coaxial cable and the control cable to the transceiver as illustrated below.

tGround the transceiver, AT-140 and shield cable of the control cable via the ground terminal.

• See pgs. 2 and 7–10 for grounding details.

IMPORTANT!— AT-140

NEVER ground the AT140 via the mounting plate. It is not connected to ground internally.

Rubber vulcanizing tape

eFix both of the coaxial and control cables to pro- tect the inside connections.

DO NOT pull the antenna and control cable re-

ceptacles. This may cause disconnection (in the

AT-140), internal connector damaged or bad

connection.

Ground terminal

Mounting plate

Icom HF transceiver

AT-140

Ground

Ground

5

Image 8
Contents AT-140 Word Definition QtyMiscellaneous Items Antenna System Antenna for shipAntenna for land operation Required antenna element lengthCoaxial cable Ground and counterpoiseControl cable InstallationsInstallation outline PL-259 connector MountingMounting on a Mast/Metal pole Mounting on a flat surfaceCable connections IMPORTANT!- AT-140Control Cable Signals Terminal informationStart voltage Star Key voltage KEYTransceiver setting IC-M700 with serial number 2500 and belowOther IC-M700 and IC-M700TY IC-78 IC-M710/RT, IC-M700PRO IC-M802Specifications Unit Description and SpecificationsUnit description Kamiminami, Hirano-ku, Osaka 547-0003 Japan