Extron electronic manual RM 1000M Rack Mounting Kit User Guide, Overview, +400.883.1568

Page 1

RM 1000M Rack Mounting Kit • User Guide

Overview

 

 

 

 

 

 

 

 

:

 

 

 

 

 

 

 

 

 

ANT

 

for

 

 

 

 

 

 

 

T

 

.com

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

extron

 

 

 

 

 

IMPOR.

1000

Series

 

 

 

 

towww

 

.

 

 

 

 

 

connecting

Refer

 

 

TLP

 

 

 

ce

 

 

 

e

 

sour

 

the

completebefor

 

 

 

 

 

 

guide

 

thepower

 

 

user

 

to

 

 

 

 

 

 

 

 

oduct

 

 

 

 

 

 

 

 

the

pr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This guide provides instructions for an experienced installer to mount and install the Extron TLP 1000MV TouchLinkpanel in a standard 19 inch equipment rack, with 5U of vertical space. For complete instructions about installing and calibrating the TouchLink panel, see the TLP 1000MV and TLP 1000TV User Guide, which is available on the Extron website (www.extron.com).

Preparing and Installing the RM 1000M Mounting Kit

To mount the TLP 1000MV in any standard 19 inch equipment rack, follow these instructions:

1.If necessary, disconnect any cables that are attached to the TouchLink panel.

2.Run cables to the rack. Provide some slack in the cable for installing the TLP 1000MV

3.Secure the RM rack mount plate to the rack using the rack mount screws provided by the manufacturer of the rack.

Mounting the TLP 1000MV

1.Remove the faceplate from the TLP 1000MV and ensure that all the locking arms are flush with the unit.

2.Push the TouchLink panel through the opening in the RM 1000M.

3.You may secure the TLP 1000MV to the RM 1000M using the locking arms Ñ or mounting screws Ö.

ÑTighten the five screws for the locking arms (three on the top and two on the bottom of the TLP 1000MV). As the screws tighten, the locking arms rotate and clamp against the back of the RM 1000M, holding the TouchLink panel in place. Do not overtighten the screws.

OR

ÖUse four mounting screws (#6-32 x 0.375") to secure the TouchLink panel to the nut inserts in the RM 1000M. Do not overtighten the screws.

Secure RM 1000M to Rack

2

RM 1000M

3a Tighten screws to rotate locking arms.

OR

4. Connect the cables to the

 

 

 

3b Secure unit with

back of the TLP 1000MV. If

 

 

 

mounting screws (4).

 

1 4 Faceplate Snaps to Unit

 

 

necessary, carry out an initial

 

Screws (provided

calibration of the TouchLink

(4 plcs. ea. side)

 

 

 

 

by rack manufacturer)

panel, and replace the

 

 

 

 

 

 

 

 

 

faceplate. For complete instructions about cabling and calibration, see the TLP 1000MV and TLP 1000TV User Guide.

Extron USA - West

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

Headquarters

 

 

 

 

 

 

+800.633.9876

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

+400.883.1568

+971.4.2991800

+81.3.3511.7656 FAX

+971.4.2991880 FAX

Inside USA/Canada Only

Inside USA/Canada Only

Inside Europe Only

Inside Asia Only

Inside China Only

 

 

+1.714.491.1500

+1.919.863.1794

+31.33.453.4040

+65.6383.4400

 

+86.21.3760.1568

 

+1.714.491.1517 FAX

+1.919.863.1797 FAX

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

+86.21.3760.1566 FAX

 

© 2011 Extron Electronics All rights reserved. www.extron.com

68-2098-01 Rev. A

02 11

Image 1
Contents RM 1000M Rack Mounting Kit User Guide Preparing and Installing the RM 1000M Mounting KitOverview Mounting the TLP 1000MV