Extron electronic user manual RM 700M Mounting Kit Installation Guide, Overview

Page 1
RM 700M

RM 700M Mounting Kit Installation Guide

Overview

The Extron® RM 700M allows the TLP 700MV TouchLinkpanel to be mounted in a standard rack. The RM 700M uses 5 U of vertical space in a standard 19 inch equipment rack.

This guide provides basic instructions for an experienced installer to mount and connect the TLP 700MV.

Using the RM 700M mounting kit

To mount the TLP 700MV in any standard 19" equipment rack, follow these instructions:

1.Disconnect all cables from the TLP 700MV.

2.Run cables for video, network and power to the rack.

3.Secure the RM 700M to the rack, using the screws provided by the rack's manufacturer.

Faceplate snaps to unit. (4 plcs ea side)

4.Remove the faceplate from the TLP 700MV and ensure

that all the locking arms are laying flush with the unit.

5. Push the TLP 700MV through the hole in the mounting kit and tighten the six screws for the locking arm. As the screws tighten, the locking arms rotate and clamp against the back of the mounting kit, holding the TLP 700MV in place.

Secure RM 700M to rack.

Screws (6) Provided by Manufacturer

Tighten screws to rotate locking arms.

6.Connect the cables to the rear panel connectors.

Connect the LAN port to the network with a straight-through cable.

Connect an S-video or composite video source to the unit, using these two BNC connectors:

For S-video, connect the Y (luminance) signal to the VID/Y input and the C (chrominance) signal to the C input.

For composite video, connect the input to the VID/Y input.

Connect the power input to a 12 VDC, 1.0 A power supply, using the 2-pole captive screw connector.

Power input

Video inputs (2)

LAN input

TLP 700MV Rear Panel

7.If you do not plan to calibrate the TLP 700MV immediately (see the TLP 700MV user's manual), replace the faceplate by pressing the catches on the faceplate into the corresponding holes on the sides of the panel.

Extron USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794 +1.919.863.1797 FAX

Extron Europe

Extron Asia

Extron Japan

+800.3987.6673

+800.7339.8766

+81.3.3511.7655

Inside Europe Only

Inside Asia Only

+81.3.3511.7656 FAX

+31.33.453.4040

+65.6383.4400

 

+31.33.453.4050 FAX

+65.6383.4664 FAX

 

 

 

 

© 2009 Extron Electronics. All rights reserved.

Extron China

+400.883.1568

Inside China Only

+86.21.3760.1568 +86.21.3760.1566 FAX

Extron Middle East

+971.4.2991800 +971.4.2991880 FAX

68-1793-01 Rev. A 08 09

Image 1
Contents Using the RM 700M mounting kit RM 700M Mounting Kit Installation GuideOverview TLP 700MV Rear PanelUL Guidelines for Rack Mounting