INSTALLATION CONSIDERATIONS (CONTINUED)
INTELLIPAD WIRING
When you are placing both a IntelliPad and a sensor (or two keypads) in one room you may “daisy- chain” using a single cable. A cable is run between the keypad and the sensor and a single cable is run from either the sensor back to the MSU250.To prevent data feedback an IN4003 blocking diode is inserted on the data (IR) line between the IntelliPad and the sensor. The cathode, or blocking side of the diode, faces the IntelliPad. (Figure 5). Note that status wire is connected to IntelliPad’s status
(+) connector.
Figure 5
An IR sensor cable is
SENSOR/KEYPAD CABLE
The MSU250 connects to IR sensors and the IntelliPad with
run of 500’ (152.4m). Flasher cable Niles infrared flashers come supplied with a 10’ (3m)
| (CONTINUED ON NEXT PAGE) |
NILES AUDIO CORPORATION – | 7 |