Hunter Fan 81003, 81001 manual Preventative Maintenance

Page 2

W a r n i n g

TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

1.Use this unit only in a manner intended by the manufacturer. If you have questions, contact the manufacturer at the phone number or address listed in the warranty.

2.Before installing, servicing, or cleaning the unit, disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot lock the circuit breakers in the off position, securely attach a prominent warning device, such as a tag, to the service panel.

3.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.

4.Sufficient air is needed for proper combustion and exhaust- ing of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards,

such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities.

5.When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities.

6.Ducted fans must always be vented to the outdoors. Keep ducting as short and as straight as possible.

7.Acceptable for use over a bathtub or shower when connected to a GFCI protected branch circuit.

8.Install fan at least 5 feet (1.52 m) above the floor.

9.Never place a switch where it can be reached from a tub or shower.

10.This unit must be grounded.

11.For supply connection, use wires suitable for at least 90º C (194º F).

C A U T I O N

1.For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials.

2.To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.

3.DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward.

4.Please read specification label on product for further information and requirements.

W a r n i n g

DISCONNECT

ELECTRIC

POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT

PREVENTATIVE MAINTENANCE

A clean fan provides better service. Disconnect the power supply and clean the fan as listed below.

TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders.

TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screw- driver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing.

METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

MAINTENANCE

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time.

2

41937-01 3/29/2006

05-HF-025_EngS_3.29.06.indd 2

3/29/06 7:33:52 PM

Image 2
Contents Installation I d e Preventative Maintenance Before Installation 75184-01-13305-HF-025EngS3.29.06.indd A11 New ConstructionA14 A15A21 A22 A18A19 B13 B11B12 B15B19 B16B17 B18 B20Attaching the Grille B22B23 Connect wiring harness. do not Allow the Fixture to Trouble Shooting SolutionWarranty Limited WarrantyFrisco Avenue, Memphis, Tennessee Desde Í a S t a l a c i ó nV E R T E N C I a Antes de la instalación Verifique todos los05-HF-025Sp3.29.06.indd Escoja la opción de instalación Construcción nuevaConecte los alambres como se muestra A21 Vaya al pasoConstrucción existente Instale la placa de cubierta del cableado Vaya al paso En la página 24 para Fijar la rejilla Fijación de la rejillaDE Iluminación Cuelgue DEL Mazo DE Cables Solución de problemas SoluciónGarantía Garantía LimitadaFrisco Avenue, Memphis, Tennessee Impreso en China
Related manuals
Manual 28 pages 55.43 Kb Manual 14 pages 14.85 Kb

81001, 81003 specifications

The Hunter Fan 81003 and 81001 models are part of Hunter's esteemed line of ceiling fans, designed to provide both style and functionality in your living spaces. Known for their exceptional craftsmanship and innovative technology, these fans are perfect for homeowners who seek comfort and aesthetic appeal.

One of the standout features of both the Hunter 81003 and 81001 is their robust motor system. Equipped with a powerful WhisperWind motor, these fans operate quietly while delivering optimal airflow. This motor is designed to circulate air efficiently, making it suitable for various room sizes without generating excessive noise, allowing for peaceful evenings or productive work hours.

Another notable characteristic of these models is their versatile design options. The Hunter 81003 typically boasts a contemporary look with sleek lines and a modern finish, making it an ideal choice for contemporary or transitional decor. Meanwhile, the Hunter 81001 embraces a more traditional aesthetic, featuring elegant detailing and classic finishes that seamlessly blend with vintage and rustic interiors. This variety ensures that homeowners can find a fan that complements their existing decor while improving comfort.

The Hunter 81003 and 81001 fans also feature multi-speed settings, offering customizable airflow according to personal preferences and seasonal changes. Whether you need a gentle breeze on a warm summer day or stronger airflow during more humid conditions, the adjustable speeds allow for an enhanced user experience.

Furthermore, both models come equipped with integrated lighting options. With built-in light kits or compatibility for standard bulbs, the fans offer ambient lighting that can illuminate your space effectively. Many users appreciate this dual functionality, as it saves on ceiling space and combines light and cooling into one stylish fixture.

Installation is made easy with these models, thanks to their user-friendly design and comprehensive instructions. Hunter also emphasizes durability, utilizing high-quality materials to ensure longevity and reliable performance over time. The fans are also compatible with various smart home systems, offering tech-savvy users the ability to control their fans remotely, adding an extra layer of convenience.

In summary, the Hunter Fan 81003 and 81001 stand out for their whisper-quiet operation, stylish designs, customizable settings, integrated lighting options, and user-friendly installation process. These fans embody Hunter's commitment to quality and innovation, making them a perfect choice for enhancing comfort in any home environment.