SoundwebTM
Use
The 9014 requires
•Connect a 24v 1A DC power supply to the 2.4mm barrel connector. Up to nine more 9014s may be powered from the paralleled combicon connector.
•Connect a
A pair of 9014 Fibre Interface units are used to replace a standard category 5 Soundweb network cable. Each fibre cable will transfer 8 channels of digital audio plus control data.
To utilise the fibre system, each end of the fibre link requires one 9014 device. Each device is equipped with an
Two fibre cables are then required to connect between 9014 devices - this is to enable the
Network socket
This connects to either the Network Out socket or the Network In socket on another unit.
The connecting cable is CAT. 5 network cable, terminated with RJ45 connectors, with all 8 cores wired straight through.
Note that the twisted pairs in any CAT.5 network cable must be wired to the following pin pairs at each terminal:
1
Note:
Ensure that all Out sockets are connected to their correct In sockets at each end of every cable. Connecting In - In (or Out - Out) will result in improper operation of the network.
124