AMX HT04, HT12 Connect a Mouse, Keyboard and VGA Monitor, Connect the Power Cable and Apply Power

Page 2

Step 1: Connect a Mouse, Keyboard and VGA Monitor

Connect a PS/2 mouse and keyboard, and a VGA monitor directly to the server to access the on-board interface, called the MAX Admin Menu (FIG. 3). You’ll use the options in the Admin Menu to configure communication settings and add/remove MAX-AVP Audio-Video Players as well as MAX-AVM and MAX-AOM modules.

Note: Alternatively, you can access the MAX Admin Menu via Telnet, using the Server Configuration feature in the WInMAX software. This requires that the server is configured with an IP address and Subnet Mask settings which are appropriate for your network configuration. Refer to “Step 6: Install and Configure WinMAX Software” for details.

Step 2: Connect the Power Cable and Apply Power

Note: It is recommended that you use a UPS with the MAX-HT server, modules, and ethernet switch (if applicable).

1.Connect the power supply, using the supplied power cord.

2.Flip the Master Power switch to the On position.

3.Push the Power On/Off toggle switch to apply power.

4.Allow up to one minute for the server to boot-up.

Shutting Down the MAX-HT Server

Always shut down the server via the Shutdown command in the MAX Admin Menu (see below). This allows the operating system to shut down completely before power is removed, and prevents the time-consuming re-initialization process that results from an improper shut down (and cannot be cancelled).

Step 3: Access the MAX Admin Menu

Once the boot-up process is complete, the MAX Admin Menu (FIG. 3) is displayed:

1.In the MAX Admin Menu, select Output Module Setup > Add Output Module > AOM.

2.In the Enter Output Number field, specify the first of up to 4 outputs on the server that you want to assign to this AOM (range = 1 - 33).

Each AOM requires up to 4 server outputs to accommodate the 4 audio output/ zones provided by each AOM. Since the MAX-HT12 supports two AOMs (one on each USB port), you can assign up to 8 server outputs. Select OK.

3.In the Enter USB Port Number field, enter the number of the USB port (1 or 2) on the server that this MAX-AOM will be physically connected to. Select OK.

4.In the Enter AOM Output Number field, specify which audio output/zone on the MAX-AOM (1-4) you are adding to the specified server output. Select OK.

5.A message is displayed to notify you that the AOM module has been added to the system. Select OK to return to the Output Module Setup menu.

Repeat these steps to assign each of the AOM’s four audio output/zones to a USB port and Output number on the server.

Notes: Always assign 4 consecutive server outputs to each MAX-AOM, even if you don’t plan to use all of the AOM’s outputs right away.

Assign the 4 server outputs (per AOM) starting either with output #1 (if there are no AVPs/AVMs on this server), or immediately after the last output assigned to an AVP or AVM.

To avoid potential confusion later, do not mix AOM outputs and AVP/AVM out- puts on the server.

6.Select Restart MAX daemon.

Step 5: Connect the Modules To the HT Server

Once the AVP players and AVM/AOM modules have been added to the server via the MAX Admin Menu, you can physically connect them to the server:

FIG. 3 MAX Admin Menu

Working With the MAX Admin Menu

Use the arrow keys on the keyboard to highlight the desired option, and press Enter to make a selection. Do not use the arrow keys on your keyboard’s numeric keypad.

Beyond this menu, press the TAB button to navigate through the elements on the pages until an asterisk appears next to the desired selection.

Press the spacebar to make a selection (press again to de-select).

For detailed descriptions of all options in the MAX Admin Menu, refer to the MAX Servers Instruction Manual.

Step 4: Add MAX-AVPs, AVMs and AOMs to the HT Server

Before you can use MAX-AVP Audio-Video Players MAX-AVM or MAX-AOM modules, they must each first be added to the server, via the Output Module Setup options in the MAX Admin Menu. You should add the modules/players to the server before making any physical connections.

Adding MAX-AVP Players and/or MAX-AVM Modules

Complete these steps for each MAX-AVM Audio-Video module and/or MAX-AVP Audio-Video Player that you want to add to the MAX-HT:

Note: HT Servers treat MAX-AVPs exactly the same as MAX-AVMs, and the process of adding them is identical.

1.In the MAX Admin Menu, select: Output Module Setup > Add Output Module > AVM.

2.In the Enter Output Number field, specify the output on the server that you want to assign to this AVP or AVM (range = 1 - 33). Each AVP/AVM requires one output. Select OK to proceed.

Note: The server will not allow you to assign a module to an output/zone that is already in use. Select Output Module Setup > View to review the current output/zone assignments.

3.In the Enter Serial Number field, enter the Setup Serial (Key) Number. This number is printed on a decal located on the bottom of each AVM/AVP enclo- sure. The system will notify you that the AVP (or AVM) has been added to the system.

Note: AVMs use a Setup “Serial” Number; AVPs use a Setup “Key” Number.

4.Select OK to return to the Output Module Setup menu, select OK again to return to the main menu.

5.Select Restart MAX daemon.

Adding MAX-AOM Audio-Only Modules

Complete these steps for each MAX-AOM module that you want to add to the HT:

Note: When connecting USB cables to the HT server, always plug into the USB 1 port first. The USB 1 port is located on the right side of the rear panel (see FIG. 1).

Connecting MAX-AVPs and/or MAX-AVMs

Note: Multiple AVMs/AVPs require a GB Ethernet switch (not included).

1.Connect the audio outputs, using either one of two options:

a.Use a mini-stereo to RCA adapter for analog audio output

b.Use a coaxial cable for digital audio output

2.Use a S-Video cable to connect the video output on the AVM or AVP to a dis- play device (MAX-AVMs also support VGA connections).

3.Use ethernet cables to connect the ethernet port on the AVM or AVP to a GB ethernet switch (not included), and the GB ethernet switch to the A/V OUT con- nector on the server.

4.Connect the included power supply.

5.Push the power button on the front panel of the AVM, and allow up to one minute for the module to boot up. On the AVPs, the power switch is on the rear panel.

Note: Power up the MAX-HT before applying power to the AVP(s) and/or AVM(s).

Connecting MAX-AOM Modules

Note: Do not use a USB hub with MAX-HT servers or AOM modules.

1.Connect the MAX-AOM(s) to an audio system (amplifier, switcher, etc.), using one of two options:

a.Use RCA cables for analog stereo output (L and R)

b.Use a coaxial cable for digital audio output (D)

2.Connect the included power supply to apply power to the AOM.

3.Use the supplied USB cable to connect the AOM module to a USB port on the server.

Note: Power up the AOM(s) before connecting them to the server.

Step 6: Install and Configure WinMAX Software

Once the AVP players and AVM/AOM modules have been added and connected to the server, you can use the WinMAX software application to initiate and control playback of movies or music. If you intend to connect to the MAX-HT via a LAN connection, verify that the PC is communicating properly with the network, and that the server is powered and booted up.

1.Use an ethernet cable to connect the ETHERNET CONTROL port on the server to the LAN that the PC running WinMAX is on.

2.Launch the WinMAX software on your PC and open the System Information tab, where you can specify the network address of the server.

3.Change the Server’s IP Address or URL field to match that of the server you are connecting to. Click on the disk icon next to the text-entry field to save this configuration.

If you are connecting to the server via a direct connection with a PC (using a crossover ethernet cable), verify that the IP Address of the Network card in your PC is in the same range as the server, but not the same as the server. For example a network card setting of 192.168.1.31 will work with a server IP address of 192.168.1.30.

4.The blank fields should fill in momentarily, indicating that the MAX-HT has been recognized.

If You Don’t Connect

Check ethernet cables and verify that all connections are intact.

If you are connecting to the server via a PC network, be sure that the IP address and Subnet Mask settings are appropriate for your network configuration. Consult your network administrator for help with this.

You can use WinMAX to establish a Telnet connection with the MAX-HT to access the MAX Admin Menu: in the WinMAX System Information tab, click on Server Configuration. You will be prompted for a User Name and Password. These are case sensitive, and by default:

User Name = root

Password = mozart

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

93-2178-14

REV: C

 

065-004-2808 6/06

©2006 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

Image 2
Contents Related Documents Product SpecificationsInitial Setup and Configuration Network Segment Layout for MAX-HT ServersInstall and Configure WinMAX Software Connect the Power Cable and Apply PowerAccess the MAX Admin Menu Connect a Mouse, Keyboard and VGA Monitor