Vizio VS-900 manual Examples, Remote Dialing

Page 8

TOA VS-900 Programmer’s Guide

Examples

1. Remote Dialing

The data sequence below will remote dial Master Station #1 in Exchange #1 to dial Sub-Station #105 and initiate communication. The “CC” (Clear) is included to terminate any current Master Station functions. Note: The total Dialing Contents must be 32 bytes.

Field Name

Length

 

(Bytes)

Value Description

Direction

DLE

1

ENQ

1

DLE

1

ACK

1

DLE

1

STX

1

Remote Dial

1

Exchange #

2

Master Station #

1

Dialing Contents

32 Bytes

DLE

1

ETX

1

BCC

1

DLE

1

ACK

1

DLE

1

EOT

1

10H

05H

10H

06H

10H

02H

4EH

30H 31H

31H

43H 43H 31H 30H 35H

20H 20H 20H 20H 20H 20H

20H 20H 20H 20H 20H 20H

20H 20H 20H 20H 20H 20H

20H 20H 20H 20H 20H 20H

20H 20H 20H

10H

03H

79H

10H

06H

10H

04H

Delimiter

Enquiry

Delimiter Acknowledge Delimiter Start Of Text Remote Dialing Command EXCHANGE # "01" MASTER # "1" "CC105"

Delimiter

End Of Text

Block Check Character

Delimiter

Acknowledge

Delimiter

End of Transmission

PC to VS-900MF

VS-900MF to PC

PC to VS-900MF

VS-900MF to PC

PC to VS-900MF

8

Image 8
Contents VS-900 Table of Contents Useful Software Tools OverviewVS-900 Documentation Connecting to the VS-900MF Mainframe STX Message Communication SpecificationsMessage Packaging Remote Dial Command Command Remote Dial Exchange #Log Data Output Request Examples Remote DialingRemote Dial Exchange # Master Station # Dialing Contents Remote Dialing All Call PagingLog Data All ExchangesON/OFF Status 31H = On 30H=OffStation Call Reception Call Operation CompletionStart of Normal Conversation TimeStart of normal ConversationCall From Normal Sub-station Decimal equivalent of aboveAppendix a Log Status Messages Status # 2 Bytes Description Line Dec HexCall Appendix B Ascii Character Codes