Chauvet FX 2.0, RGX 2.0 user manual Appendix, General Troubleshooting

Page 13

5. APPENDIX

General Troubleshooting

SYMPTOM

POSSIBLE CAUSE(S)

POSSIBLE ACTION(S)

 

 Excessive circuit load

 Check total load placed on the

Breaker/Fuse

electrical circuit.

 

keeps blowing

 Short circuit along the power

 Check for a short in the electrical

 

wires

wiring (internal and/or external).

Device does not

 No power

 Check for power on Mains.

power up

 Loose power cord

 Check power cord

 

 Wrong DMX addressing

 Check Control Panel and unit

 

addressing

 

 

Product is not

 Damaged DMX cables

 Check DMX cables

 Wrong polarity settings on the

 Check polarity switch settings on

responding to

controller

the controller

DMX

 Loose DMX cables

 Check cable connections

 

 

 Faulty DMX interface

 Replace DMX input

 

 Faulty Main PCB

 Replace Main PCB

 

 Non DMX cables

 Use only DMX compatible cables

 

 Bouncing signals

 Install terminator as suggested.

 

 Long cable / Low level signal

 Install amplifier right after product

Loss of signal

with strong signal.

 

 Too many products

 Install an optically coupled DMX

 

 

splitter after unit #32.

 

 

 

 Interference from AC wires

 Keep DMX cables separated from

 

power cables or black lights.

 

 

If you still have a problem after trying the above solutions, please contact CHAUVET®

Technical Support.

MinLasers 2.0 User Manual

13

August 2011

Image 13
Contents Page Table of Contents Before YOU Begin Safety Instructions Laser Safety Notes Non Interlocked Housing WarningTop Front Rear Bottom Laser Safety Label ReproductionLaser Compliance Statement Laser Emission DataProduct Overview IntroductionAC Power SetupMounting Coupler Clamp August Proper Usage Wireless Remote IR Manual ModeOperating Instructions Appendix General TroubleshootingProduct Maintenance General Information Returns ProcedureIEC Technical Specifications