WIRING

POWER AND GROUND

To ensure maximum output from your Human Reign Unleashed amplifier, use high quality, low-loss power and ground cables and connections. The Human Reign Unleashed amplifiers will accept up to 2 gauge power and ground cables. Determine from the chart below the minimum gauge power and ground wire for your application.

 

 

 

less than 1

 

 

m

ore than 10

´

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HRU. 2

 

 

 

 

 

 

 

 

 

2 or 4 gauge

2 gauge only

 

 

 

 

 

 

 

 

 

 

 

HRU. 4

 

 

2 or 4 gauge

2 gauge only

CIRCUIT BREAKERS AND FUSES

EXTERNAL

Like all audio components, the Human Reign Unleashed amplifier must be fused near the battery. A fuse or circuit breaker must be located within 18” of the battery. This will prevent a fire in the event of a shorted cable. See the chart below to determine the correct fuse value.

INTERNAL

The Human Reign Unleashed amplifiers need to be fused with an automotive-type fuse or circuit breaker. In the event of a blown power supply fuse(s), replace with replace with the correct value fuse found in the chart below.

Never replace the fuse with a higher value than what is supplied. This may result in amplifier damage and will void the warranty!

Human Reign Unleashed Amplifier Fuse Values

 

 

 

 

 

 

 

 

Battery Fuse / Circuit Breaker

 

 

 

 

 

 

HRU. 2

 

 

 

 

 

200 amp

 

 

 

 

HRU. 4

 

 

140 amp

12

Image 12
Contents Human Reign Unleashed U T I O N Table of Contents Design Features Section and 24dB/octave for the lowpass section HRU KEY to Callouts HRU KEY to Callouts Hawkins Bass Control Theory and Use Phase Switch Wiring Circuit Breakers and FusesSignal Cable Remote TURN-ONSpeaker Cable Installation and Mounting Level Setting Trouble Shooting Trident Protection CircuitryService Specifications