AMX DMS (FG2408-01XX) quick start Rear Components, Specifications, Dynamic Menu System

Page 1

Quick Start Guide

Mio Modero DMS Keypad metallic

Overview

Installation

The Mio Modero DMS device family provides a wide range of control capabilities in the form of user specified buttons that are functional yet recherché.

Mio Modero DMS keypads are equipped with an LCD menu display with 8 pushbuttons for navigation and menu selection.

Note: To avoid any damage to the electronic component, installation must be performed in an ESD safe environment. The device and conduit box must have an Earth ground.

The installation section addresses the mounting and wiring of the Mio Modero DMS. After you have completed the installation you must consult Necessary Device Setup.

Menu items

Menu Up

Menu select pushbuttons

Menu Down

Rear Components

The rear components of the Mio Modero DMS (FIG. 2) are as follows:

Ethernet Port (PoE)

(Front View)

Magnetic Posts

FIG. 1 Mio Modero DMS Device Family

Specifications

Mio Modero DMS (FG2408-01XX) Specifications

Power 12 VDC / PoE:

 

 

Maximum power consumption (PoE):

5.5 Watts

Maximum startup (rush) current (PoE):

150 mA @ 50 VDC

Maximum continuous current (PoE):

100 mA @ 50 VDC

Maximum power consumption (DC):

5.0 Watts

Maximum startup (rush) current (DC):

525 mA @ 13.5 VDC

Maximum continuous current (DC):

350 mA @ 13.5 VDC

 

 

 

Front Panel Components:

LCD display

 

8 pushbuttons

 

 

 

Rear Panel Connectors:

Ethernet Port (PoE)

 

2-pin 3.5 mm mini-Phoenix (female) connector

 

4 Magnetic Posts

 

Ground wire

 

 

 

Dimensions (HWD):

• 6.25 (158.8 mm) x 3.50 (91.4 mm) x 3.93 (99.7 mm)

(inside of conduit box)

 

 

 

 

Supported Fonts:

Only True Type Fonts

 

 

 

Weight (range):

Device - .55 lbs (.25 kg)

 

 

 

Operating Environment:

Operating Temperature: 0° to 40° C (32° to 104° F)

 

• Storage Temperature: -10° to 60° C (14° to 140° F)

 

 

Mounting:

The Mio Modero DMS is installed in one of three ways:

 

Rough-in mounting

 

• Expansion clips for pressure mounting

 

• No tabs for brick and mortar mounting

 

 

Available Color Schemes:

Gold (GL), Silver (SL)

 

 

 

Included Accessories:

2-pin 3.5 mm mini-Phoenix connector (41-5025)

 

Conduit box (FG039-11)

 

Mounting kit (KA2250-01)

 

 

 

Other AMX Equipment:

NXA-ENET24PoE: Managed Ethernet Switch, Power

 

 

Over Ethernet (FG2178-61)

 

 

 

Dynamic Menu System

Using the KeypadBuilder application available for download from www.amx.com, the Mio Modero DMS is programmed with a Dynamic Menu System (DMS) that is navigated via the 8 pushbuttons and LCD display area. See the KeypadBuilder Instruction Manual for more information on programming Mio Modero DMS devices.

2-pin

3.5 mm mini-Phoenix

(female) connector

FIG. 2 Mio Modero DMS Rear Components

Connections and Wiring

The Mio Modero DMS device is powered either via 12VDC or Power over Ethernet (PoE). If both the 12 VDC and PoE power sources are connected, by default the device draws power from the 12 VDC. If the 12 VDC source is disconnected, the PoE automatically supplies power after a device reboot.

Note: Do not connect power to the Mio Modero DMS until the wiring is complete.

Preparing captive wires for the 2-pin 3.5 mm mini-Phoenix connector

You will need a wire stripper, and flat-blade screwdriver to prepare and connect the captive wires.

1.Strip 0.25 inch (6.35 mm) of wire insulation off all wires.

2.Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section.

3.Turn the screws clockwise to secure the wires in the connector.

Note: Do not over-torque the screws; doing so can bend the seating pins and damage the connector.

Using the PSN NetLinx connector for power

The PWR and GND wires from the 12 VDC power supply must be connected to the corresponding location on the 2-pin 3.5 mm mini-Phoenix connector (See the KeypadBuilder Instruction Manual for an illustration).

1.Insert the PWR and GND wires on the terminal end of a PSN 2-pin 3.5 mm mini- Phoenix cable. Match the wiring locations of the +/- on both the power supply and the terminal connector.

2.Tighten the clamp to secure the two wires.

3.Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the power supply.

Using the Ethernet port for power (PoE)

Connect your CAT5/CAT6 Ethernet cable to the port shown in FIG. 2. (See the Mio Modero DMS & Mio Modero DMS Pinnacle instruction manual for an illustration and cable pinouts).

Image 1
Contents Connections and Wiring SpecificationsUsing the PSN NetLinx connector for power Using the Ethernet port for power PoEAccessing The Setup Mounting Procedures Expansion Clip InstallationNecessary Device Setup IP Settings