Fisher TW-7700 manual Accessories, Coupling Clamp, Headsets

Page 7

ACCESSORIES

Coupling Clamp

The coupling clamp is useful when the utility is exposed, and a direct connection is not possible. It is plugged into the same plug-in socket as the ground-plate/ground-rod assembly. The coupling clamp only operates at the 82 kHz frequency. The coupling clamp will fit around utili- ties that are 3-¼ inches in diameter or smaller. The length of the cable is approximately 10 feet.

Coupling Clamp Applications Diagram

A. The coupling clamp is for all tracing applications with con- ductors exposed; exception, an open circuit at line’s termination.

B. A ground must be provided for the proper current flow when the coupling clamp is used at a ter- mination.

C. The coupling clamp must be used between the grounding and where the line goes under- ground.

D. Trace signal will return to ground when incorrectly coupled.

E. Signal will be transmitted in both directions when connect- ing is midway in a long conductor.

F. Drop lines or laterals divide the signal strength in half at each junction.

This represents a jumper

Headsets

Fisher Research Laboratory has a variety of headsets avail- able.

•Ultra-quiet deluxe Fisher Phones. High quality sound while reducing the outside noise.

•Standard Stereo Headphones

•Single Earpiece Headset. Enables the operator to effec- tively listen to the TW-7700 and remain aware of noise in close proximity.

7

Image 7
Contents TW-7700 Contents Description Transmitter TW-7700 TransmitterTW-7700 Transmitter TW-7700 Receiver Numeric Display No SignalDisplay Frequency Modes Left/Over Target/RightHeadsets AccessoriesCoupling Clamp Tracing Operating InstructionsInductive ConductiveMoisture Low Receiver Signal StrengthDepth Accuracy Nearby UtilitiesSubject to improvement or modification without notice SpecificationsPage 200 W. Willmott Rd Los Banos, CA Tel 209.826.3292 Fax Fisher Research Laboratory