Agilent Technologies 8472B service manual Warranty, Certification

Page 3

Warranty

Certification

Agilent Technologies certifies that this product met its published specifications at the time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (NIST, formerly NBS), to the extent allowed by the Institute’s calibration facility, and to the calibration facilities of other International Standards Organization members.

Warranty

This Agilent Technologies system product is warranted against defects in materials and workmanship for a period corresponding to the individual warranty periods of its component products. Instruments are warranted for a period of one year. During the warranty period, Agilent Technologies will, at its option, either repair or replace products that prove to be defective.

Warranty service for products installed by Agilent and certain other products designated by Agilent will be performed at Buyer’s facility at no charge within Agilent service travel areas. Outside Agilent service travel areas, warranty service will be performed at Buyer’s facility only upon Agilent’s prior agreement and Buyer shall pay Agilent’s round trip travel expenses. In all other areas, products must be returned to a service facility designated by Agilent.

For products returned to Agilent for warranty service, Buyer shall prepay shipping charges to Agilent and Agilent shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties, and taxes for products returned to Agilent from another country.

Agilent warrants that its software and firmware designated by Agilent for use with an instrument will execute its programming instructions when properly installed on that instrument. Agilent does not warrant that the operation of the instrument, or software, or firmware will be uninterrupted or error free.

LIMITATION OF WARRANTY. The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance.

NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. AGILENT SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

EXCLUSIVE REMEDIES. THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES. AGILENT SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,

8472B Operating and Service Manual iii

Image 3
Contents 8472B Crystal Detector Restricted Rights Legend Warranty WarrantyCertification Assistance Asia Call Center Numbers Service and SupportInstrument Markings Safety and Regulatory InformationContents Features Mating ConnectorsDescription Initial Inspection Storage and Shipment InstallationSpecifications SpecificationsOperating Information Operator’s Checks Peak Power MeasurementHarmony Frequency Comparison Measurement Application Reflectometer ApplicationPerformance Tests Service Instructions Service Instructions 8472B Crystal Detector Assembly Replaceable Parts

8472B specifications

Agilent Technologies 8472B is a high-performance microwave amplifier that has earned a reputation for reliability and precision in various applications including telecommunications, signal testing, and RF research. As a compact and versatile device, the 8472B combines cutting-edge technology with user-friendly functionality, making it a staple in many laboratories and test environments.

One of the standout features of the 8472B is its impressive frequency range. It operates effectively from 10 MHz to 20 GHz, which accommodates a wide array of microwave testing scenarios. This range ensures that it can handle both low and high-frequency signals, making it suitable for various applications, including wireless communication systems and radar testing.

The amplifier offers a nominal gain of 20 dB, with the ability to provide consistent performance across its frequency spectrum. This high gain factor is essential for amplifying weak signals without introducing significant noise, thus enhancing the quality of the transmitted signals. Additionally, the 8472B features a low noise figure, typically around 4 dB, which is crucial for maintaining signal integrity during amplification.

Another significant characteristic of the 8472B is its robust design, which includes overvoltage protection features. This makes the device resilient to unexpected voltage spikes, ensuring longevity and stability in diverse operating conditions. The amplifier also has a wide dynamic range, allowing it to perform well under varying signal conditions.

With respect to connectivity, the Agilent Technologies 8472B typically features 50-ohm connectors, which are standard in RF applications. Its compact form factor allows for easy integration into existing test setups, whether in a bench environment or within a larger instrumentation rack.

User-friendly features like an easily accessible control panel and clear indicators provide straightforward operation, facilitating quick adjustments and real-time monitoring. The 8472B also supports a variety of power supply configurations, giving users flexibility in incorporating it into their setups.

In conclusion, the Agilent Technologies 8472B microwave amplifier embodies the ideal blend of performance, durability, and versatility. Its frequency range, gain capabilities, low noise figure, and robust design make it an exceptional choice for engineers and researchers dealing with RF and microwave applications, cementing its status as a critical tool in the field.