Bosch Appliances 400 manual Connections, First-time use, Quick install menu

Page 3

Video Recorder 400 Series

Quick install en 3

 

 

Quick install

To get the unit quickly operational, make the connections described below and then enter the relevant data in the Quick install menu. The Quick install menu appears the first time the unit is started.

Connections

Primary connections

1.Connect the cameras to the VIDEO IN BNC connectors (automatically terminated).

2.Connect monitor A to the VGA MON A output (supporting 800x600, 1024x768, or 1280x1024).

3.Connect USB mouse to a USB port.

Optional connections

1.Connect monitor B to the MON B BNC connector.

2.Connect up to 4 audio signals to the AUDIO IN RCA (CINCH) inputs.

3.Connect the AUDIO OUT RCA (CINCH) output to the monitor or an audio amplifier.

4.Connect up to 4 ALARM IN inputs (via the supplied terminal blocks).

5.Connect up to 4 ALARM OUT outputs (via the supplied terminal blocks).

6.Connect a pan/tilt/zoom control unit to the RS-485port (via the supplied screw terminal block).

7.Connect to your network via the RJ-45Ethernet port.

8.Connect a “Bosch RS232 to Bi-phase converter” to the RS-232port if required.

Powering up

Switch on all connected equipment.

Connect the power cord to the unit.

First-time use

The Quick install menu opens the first time the unit is used. Fill in the basic settings in the three tabs to get the unit operational. The unit begins recording automatically when the Quick install menu is closed.

To open the Quick install menu at any other time:

1.Press the menu key to bring up the System Control Bar.

2.Press the menu key again to enter the main menu.

– The main menu appears on monitor A.

3.Select System, then the Configuration submenu, and finally Quick install.

Navigating

Use the supplied USB mouse. Alternatively, use the following front panel keys:

Use the enter key to select a submenu or item.

Use the arrow

keys to

 

move through a menu or list.

 

Use the exit key to go back or to switch off the menu.

After bootup, the unit presents the log in screen over a quad display. The default User ID is ADMINISTRATOR, the default password is 000000 (six zeros).

Quick install menu

The Quick install menu contains three tabs: International, Continuous Recording, and Network. Click the Exit button to exit the Quick install menu. Changing Quick install settings overwrites customized settings.

International

Language

Select the language for the menu from the

 

list.

Time

Select a time zone from the list.

zone

 

Time

Select either a 12 or a 24 hour clock format.

format

 

Time

Fill in the current time.

Date

Select from three date formats which show

format

either the month (MM), the day (DD), or the

 

year (YYYY) first.

Date

Fill in the current date.

Continuous Recording

Set the Continuous Recording Resolution, Quality, Frame rate, Covert, and Audio for each profile in the table.

Network

DVR name

Enter a DVR name to be used in the

 

network.

DHCP

Enable DHCP to have IP address, subnet

 

mask, and default gateway assigned

 

automatically by the network server.

 

The actual values are displayed.

IP address,

Fill in the IP, subnet mask, and gateway

Subnet mask,

addresses when DHCP is disabled.

and Gateway

 

Bosch Security Systems

F.01U.137.406 v1.0 2009.12

Image 3