Behringer DEQ1024 manual Specifications

Page 13

ULTRAGRAPH DIGITAL DEQ1024

5. SPECIFICATIONS

ANALOG INPUTS

 

Type

electronically balanced

Connector

XLR

Impedance

22 kat 1 kHz

Max. input level

+12 or +22 dBu, switchable

CMRR

80 dB typ.

ANALOG OUTPUTS

 

Type

servo-balanced

Connector

XLR

Impedance

100 at 1 kHz

Max. output level

+12 or +22 dBu, switchable

SYSTEM SPECIFICATIONS

 

Frequency response

15 Hz to 35 kHz, +/- 3 dB

Signal-to-noise ratio

104 dBu, a-weighted,

 

22 Hz - 22 kHz

THD

0.004 % typ. @ +4 dBu, 1 kHz,

 

gain 1

Crosstalk

< -85 dB, 22 Hz - 22 kHz

BYPASS

 

Type

Relay, hard-bypass in case of

 

power failure

DIGITAL INPUTS

 

Type

XLR transformer-balanced

Standard

AES/EBU or S/PDIF

Input impedance

110

Nom. input level

0.2 - 5 V peak-to-peak

DIGITAL OUTPUTS

 

Type

XLR transformer-balanced

Standard

AES/EBU or S/PDIF

Impedance

110

Output level

2 - 5 V peak-to-peak

DIGITAL PROCESSING

 

Converter

24-bit Delta-Sigma, 64/128

 

oversampling

Sample rate

44.1 kHz, 48 kHz, 96 kHz

GRAPHIC EQUALIZER

 

Type

analog 1/3-oct EQ

Frequency range

20 Hz to 20 kHz 31 1/3-oct. bands

 

according to ISO frequencies

Bandwidth

1/3-oct.

Control range

+/-6, +/-12 dB or 0/-24 dB

 

(switchable)

FEEDBACK DESTROYER (FBD)

Type

digital signal analysis for

 

feedback identification

Filter

max. 10 digital notch filters per

 

channel, automatic feedback

 

suppression system

Frequency range

20 Hz - 20 kHz

Bandwidth

1/10-oct.

Control range

-48 dB in 6 dB-steps

MASTER

 

Gain

-9 dB to +9 dB

FILTER

 

Low Cut

20 Hz to 160 Hz (12 dB/oct.)

High Cut

2.5 kHz to 16 kHz (12 dB/oct.)

DYNAMICS

 

Type

gate and limiter with digital IGC

 

(Interactive Gain Control)

Threshold

variable: -60 to -10 dB (gate)

 

variable: -6 to +9 dB (limiter)

FUNCTION SWITCHES

 

Bypass

switch, to deactivate equalizer

 

functions

Meter in/out

selects between input and

 

output metering

Fader range

sets the maximal cut/boost

 

for the 31 bands

Standby

switches into standby mode

Pink noise

-48 dB to 0 dB

FB indicator

recognition of frequency band

 

intensity

True Curve

Algorithm for achieving filter

 

curve linearity

DISPLAYS

 

Input/output level

12-digit LED display: -48/-36/-24/

 

-18/-12/-6/-3/0/+3/+6/+9 dB/CLIP

Function switch

LED display of each switch

 

(except for clock and

 

configuration switches)

POWER SUPPLY

 

Voltage

85 to 250 V~, 50/60 Hz,

 

auto range

Power consumption

typ. 10 W

Fuse

T 1 A H

Mains connector

Standard IEC receptacle

DIMENSIONS/WEIGHT

 

Dimensions (H x W x D)

approx. 3.5" (89 mm)

 

x 19" (482.6 mm)

 

x 5.3" (135 mm)

Shipping weight

approx. 2.5 kg (5 lbs)

BEHRINGER continuously strives to assure the highest quality standards possible. Required modifications may be implemented without prior notice. Technical data and the appearance of the unit may deviate from the above values and/or illustrations.

5. SPECIFICATIONS

13

Image 13
Contents Version 1.0 June Ultragraph DigitalDetailed Safety Instructions Important Safety InstructionsUltragraph Digital Foreword Table of ContentsBefore you get started IntroductionUser’s manual Front panel Control ElementsPink Noise Limiter GateSignal flow in PRE EQ mode Rear panel ApplicationsEqualizer in the monitor path Master equalizer in sound reinforcement systemsSpecial sound effects Using the Ultragraph Digital in the studioRack mounting InstallationAudio connections Digital connections AES/EBU and S/PDIFSpecifications Warranty