3 Field Replaceable Units

The field replaceable subassemblies within the Megaplex II chassis are described below. The subassemblies in this section are:

the power supply assemblies and

the fan module assemblies.

These assemblies can be ordered as spares from AMI.

Warning

The 4U chassis has three power inlets; each one must be removed to completely disconnect the power supply.

The 4U chassis contains a 5x20mm 250V 5A slow fuse in the power supply.

Power Supply Modules Three 440 watt power supplies support the Megaplex II chassis. The power supplies are located at the rear of the chassis. Each power supply has a power sharing board, which interfaces to the power distribution board located internally in the chassis. DC power is distributed from the power supply module to the power distribution board inside the enclosure and throughout the chassis. Each power supply has an integrated fan.

These fans along with the additional chassis fans provide cooling for the chassis. Only the chassis mounted fans are replaceable. Failure of a power supply fan requires replacement of the affected power supply. To replace a power supply follow the procedure below.

Chapter 3 Field Replaceable Units

15

Image 21
Contents Megaplex II 4U Chassis Guide Revision History Table of Contents Field Replaceable UnitsIndex FTP Site PrefaceDisclaimer Safety Summary General Description of Chassis General InformationFront of Chassis Back of Chassis AC Input SpecificationsWith Megaplex Temperature Cooling Fans Connectors on Back of Chassis Drive Bays on Front of Chassis Unpacking and Inspection InstallationDrive Installation Drive Installation Drive Installation Rack-Mount Installation Brackets Field Replaceable Units Replacing a Power Supply Replacing a Fan Module Megaplex II 4U Chassis Guide Index Unpacking