Beyerdynamic SIR 320 operating instructions Technical data

Page 9

Technical data

Complies with standards IEC 914 and IEC61603-3(in normal operation)

Number of channels:

up to 32 (in dependence of type) regarding IEC 61603-2 and IEC 61603-7

Modulation:

FM

Transmission frequencies:

55 kHz - 1335 kHz in 40 kHz pattern for OR - Ch31

Intermediate frequency:

455 kHz

Operating mode:

Superhet receiver with PLL Synthesizer

Angle of reception:

120° horizontal / 100° vertical

Frequency response:

125 - 8.000 Hz

Distortion factor:

< 2 %

Signal / Noise ratio:

> 55 dB

Headphone socket:

3,5mm (DIN 455838)

Headphone impedance:

32 - 600 Ohm

Operating voltage:

3.6 ... 4.5 Volts

Power supply:

3 x rechargeable batteries NiMH 1.2V / 750 mA/h (AAA)

 

or 3 x disposable batteries 1,5V (AAA)

Operating time

up to 75 hours (rechargeable batteries)

 

up to 120 hours (disposable batteries)

Display:

seven-segment 2 digit LCD (Liquid Crystal Display) back lighted

 

(white text / black ground)

Test functions:

Battery voltage and IR-field strength via LCD

Temperature range:

(operating) +10°C ... +40°C

 

(storage) -20°C ... +50°C

Humidity:

< 80%, not condensed

Size:

150 x 50 x 25 mm

Housing:

ABS-plastic, grey

Weight:

approx. 150g (incl. batteries)

Copyright by beyerdynamic

9

Image 9
Contents SIR Page About this manual WarrantyImportant tips SIR 320 Infrared Multichannel ReceiverAbout this manual SymbolsYOU should PAY Attention to Folllowing Safety Instructions Safety information Important tipsGeneral information SIR 320 Infrared Multi-channel Receiver Contents of basic delivery AccessoriesSystem components Technical data Horizontal Characteristics of receptionVertical Front view Operating controlsLC-Display Infrared lensNavigation keys Charging contactsSide- / Rear view Battery coverCarrying clip LanyardStarting the receiver OperationAuto Switch-off function Volume control / memory functionLR03, AAA Disposable / rechargeable batteriesActivation of the service mode Service modeIR-field strength Battery voltageSystem parameters P1, P2, P3 Guard function optionMuting Channel shiftHardware reset Exit the service modeBehaviour in the charging tray Fault Possible reason Action Trouble shootingChannel receiver SIR Table of frequencies and channelsWarranty Copyright by beyerdynamic SIR SIR Infrared System Copyright by beyerdynamic