Graco 257500, 258699 important safety instructions Problem Cause Solution

Page 19

 

 

Troubleshooting

 

 

 

Problem

Cause

Solution

 

 

 

 

 

 

SmartDiescreed box

Foreign material in screed box discharge

CAREFULLY dislodge and remove foreign

leaking

opening

material.

 

Dirty screed box

CAREFULLY clean box. All moving parts

 

 

need to be free of debris.

 

 

 

 

Spring broken

Replace spring (see page 13).

 

 

 

 

Incorrect deployment rod linkage length

Adjust length (see page 14).

 

 

 

 

Incorrectly adjusted SmartDiescreed

Adjust lever (see page 14).

 

box/bead dispenser box actuator

 

 

 

 

 

Worn screed box gate

Replace gate (see Parts manual 313880).

 

 

 

 

Worn screed box trough

Replace trough (see Parts manual

 

 

313880).

 

 

 

Excessive material

Screed box not adjusted to ground

See Operation manual.

buildup when starting

 

 

Screed box open when ThermoLazeris

Synchronize ThermoLazerand screed

and stopping extruding

stationary

box motion.

 

 

 

 

 

Foreign material in screed box discharge

CAREFULLY dislodge and remove foreign

 

opening

material.

 

 

 

 

Dirty screed box

CAREFULLY clean box. All moving parts

 

 

need to be free of debris.

 

 

 

Beads not discharging

Low bead level in bead hopper

Fill bead hopper.

or discharging unevenly

 

 

Bead dispenser doors closed

Open doors as required to obtain desired

 

 

flow pattern width.

 

 

 

 

Bead dispenser drive wheel not engaged

Secure bead dispenser wheel (see page

 

 

14).

 

 

 

 

Bead dispenser drive wheel slipping

Tighten. Check air pressure (see page 14).

 

 

 

 

Debris in discharge opening of bead dispenser

Remove debris.

 

 

 

 

Debris on ThermoLazertire or bead dis-

Remove debris.

 

penser wheel

 

 

 

 

 

Moisture in beads

Remove wet beads. Dry hopper, bead

 

 

hoses and bead dispenser. Fill hopper with

 

 

dry beads.

 

 

 

Beads not discharging

Bead dispenser flow rate lever not correctly

Rotate flow rate lever to correct position.

at required flow rate

set

 

 

 

 

 

Bead dispenser drive wheel slipping

Tighten wheel and check tire pressure

 

 

(see page 14).

 

 

 

 

Bead dispenser doors not fully open

Open door fully.

 

 

 

 

Moisture in beads

Remove wet beads. Dry hopper, bead

 

 

hoses and bead dispenser. Fill hopper with

 

 

dry beads.

 

 

 

 

Moisture on road surface

Allow road surface moisture to dry.

 

 

 

 

Rough road surface

Smooth road surface.

 

 

 

 

Bead Dispenser low on material

Add material to Bead Hopper.

 

 

 

313879B

19

Image 19
Contents Related Manuals RepairTable of Contents Fire and Explosion Hazard Toxic Fluid or Fumes Hazard Connections Contacts Reading Diagnosis Terminal ConnectionsTo Check Kettle Temperature Control Calibration Kettle Temperature Control CalibrationTemperature Control Replacement Thermometer ReplacementKettle Thermometer Calibration Adjust Kettle Pilot Ignitor Electrode GapTo Check Kettle Thermometer Calibration Thermopile Replacement Installation Adjust Gas Pressure to Kettle Burners Adjust Kettle Main Burners Flame Adjust Kettle Pilot Burner FlameCleaning Kettle Pilot Burner Gas Lines Cleaning Kettle Main Burner Gas LinesReplacing Screed Box Spring Securing Bead Dispenser Wheel Linkage Rod AdjustmentScreed Box/Bead Dispenser Box Actuator Adjusting Screed Box Pivot Arm Problem Cause Solution TroubleshootingProblem Cause Solution Problem Cause Solution Problem Cause Solution Applying Material Box lever rod/lever arm Dimensions Technical DataGraco Information Graco Standard WarrantyGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN