8

8.2Alarm in

There are 4 alarm sensors in for 4 channels, all these alarm inputs are

Normally Open and shorted to ground means an alarm happens.

SENSOR 4 SENSOR 3 SENSOR 2 SENSOR 1

ALARM

CIRCUIT

8

2

1

159

There are four alarm inputs for each camera. Please connect the alarm input in the same sequence as the cameras input.

When any alarm signal is input, this quad processor will do the following:

1.switch to the full screen display of the alarmed channel.

2.Light on the channel LED.

3.turn on the buzzer.

When 2 or more alarms occur from the cameras, it will switch to quad display.

When the alarm time is over, it will go back to the normal condition that alarm occurred before.

Image 11
Contents EverPlex 4BQ Page Table of Content Safety Warning Introduction Main FeaturesSpecification Chapter I Front Panel Keypads Terminator On/Off BNC ConnectorsChapter II Back Panel Function LevelAlarm Connectors DB-15 Alarm TimeSwitch Time PowerAlarm out Alarm Circuit AlarmEverFocus Electronics Corp