EverFocus EQ120 user manual Installation Instructions

Page 12

Installation Instructions

1.Remove the cover cap from the top of the lens mount.

2.To attach a C-mount/CS-mount lens, turn the focal length adjustment ring to the appropriate position.

Note: If a C-mount lens is used, please make sure the focal length adjustment ring is set at C position before fixing the lens.

3.Screw the lens firmly onto the lens mount. Insert the lens plug in the lens connector if the auto iris lens is used.

4.Tighten the locking screw.

5.Connect the video output of the camera to a color monitor or other video device through a 75 ohm type coaxial cable with BNC female connector.

6.Plug the power cord to the outlet.

7.Once the image appears on the monitor, adjust the focus and diaphragm of the lens to obtain the best picture.

8.If the subject is not in focus when adjusting focus of lens, do focal length adjustment as following:

i.Loosen the locking screw of the focal length adjustment ring.

ii.Take picture of subject at a distance more than 20m away from the camera.

iii.Rotate the focal length adjustment ring to bring the subject in focus.

iv.Tighten the locking screw while the adjustment is completed.

8

Image 12
Contents EQ120 Page Table of Contents Page Safety Warning Do not install the camera near electric or magnetic fieldsCleaning Handle the camera with careMain Features IntroductionSpecification Sony B/W CCDMajor Parts Names and Their Functions Focal Length Adjustment Ring Lens Connector 4 pin socketControl Switches Lens MountES Electronic Shutter Off/On AGC Automatic Gain Control Off/OnLL Line-Lock Off/On Phase Adjustment VD/DD Auto Iris lens TypeIris Level Control Mounting Base and Fixing ScrewsInstallation Instructions EverFocus Electronics Corp